Доступ предоставлен для: Guest
Advanced Course in Heat Exchangers: Theory and Practice. ICHMT Symposium.
1981, Dubrovnik, Croatia

DOI: 10.1615/ICHMT.1981.AdvCourseHeatExch


ISBN Print: 978-0-07062-806-9

Failures of the Turbines Condenser Tubes with the Direct Inflow of Make-up Water into Condenser

pages 757-765
DOI: 10.1615/ICHMT.1981.AdvCourseHeatExch.480
Get accessGet access

Краткое описание

Higher ammonia concentrations in some parts of the condenser, and the higher content of oxygen introduced with make-up water, leads to condenser tube damage. The paper presents a calculation of possible ammonia concentrations in the condensate, and analyzes the possibility of reducing the oxygen content by thermal deaeration in the condenser.

Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции Цены и условия подписки Begell House Контакты Language English 中文 Русский Português German French Spain