Том 46, 2019 Том 45, 2018 Том 44, 2017 Том 43, 2016 Том 42, 2015 Том 41, 2014 Том 40, 2013 Том 39, 2012 Том 38, 2011 Том 37, 2010 Том 36, 2009 Том 35, 2008 Том 34, 2007 Том 33, 2006 Том 32, 2005 Том 31, 2004 Том 30, 2003 Том 29, 2002 Том 28, 2001 Том 27, 2000 Том 26, 1999 Том 25, 1998 Том 24, 1997 Том 23, 1996 Том 22, 1995

International Journal of Fluid Mechanics Research

DOI: 10.1615/InterJFluidMechRes.v24.i4-6.400
pages 851-860

Time-Resolved Diffraction Granulometer for Measurements in Transient Sprays

D. Lisiecki
UMR 6614/CORIA, UNIVERSITE DE ROUEN, 76821 Mont Saint Aignan Cedex, France
M. Ledoux
CORIA-UMR CNRS 6614, Universite de Rouen, Site du Madrillet Avenue de l’Universite, BP12 76801 Saint Etienne du Rouvray cedex, France

Краткое описание

The study of sprays of droplets issuing from cars injectors requires fast diagnostics synchronized on very short jet appearance. Particle sizer must furthermore be able to measure very small drops in high pressure chambers with restricted access. An instrument with capability for measuring droplet size by Fraunhofer diffraction technique with high frequency acquisition was developed. The temporal variation of the size distribution within a single diesel injection may be now recorded. An inversion program involves a generalized Lorenz Mie theory, developed in the laboratory. With this program, the scattered light of a droplet in a gaussian laser beam can be calculated. The effect of illumination profile (i.e.: ratio of the laser beam diameter on drop size) on the scattered light distribution is evaluated; the smallest beam size for a higher spatial resolution with no bias on measurement may then be calculated.
By use of a standard Malvern detector, measurements of droplet size larger than one micrometer are performed in a pressurized chamber with thick windows. Under the present configuration a special lens with short focus length and large diameter is used. An example of application to a Diesel spray is showed.


Articles with similar content:

Droplet Size Measurements in a Diesel Fuel Spray Using a Planer Laser Induced Fluorescence Method
International Journal of Fluid Mechanics Research, Vol.24, 1997, issue 4-6
N. Ishikawa, K. Tsujimura, K. Niimura
DEVELOPMENT OF PSEUDO-HIGH SPEED IMAGE PHOTOGRAPHIC SYSTEM AND THEIR APPLICATION TO DIESEL SPRAYS
ICLASS 94
Proceedings of the Sixth International Conference on Liquid Atomization and Spray Systems, Vol.0, 1994, issue
N. Shimazaki, G. Ogihara, M. Nakayama
LASER GRATING VELOCIMETRY FOR LIQUID-LIQUID SYSTEMS
ICHMT DIGITAL LIBRARY ONLINE, Vol.5, 1997, issue
Raphael Semiat
UNCERTAINTY QUANTIFICATION FOR LIQUID PENETRATION OF EVAPORATING SPRAYS AT DIESEL-LIKE CONDITIONS
Atomization and Sprays, Vol.25, 2015, issue 5
Caroline L. Genzale, Lyle M. Pickett, Julien Manin
UNCERTAINTIES IN PHASE DOPPLER MEASUREMENTS OF SPRAYS
ICLASS 94
Proceedings of the Sixth International Conference on Liquid Atomization and Spray Systems, Vol.0, 1994, issue
P. Haugen, T. Nonn