Том 46, 2019 Том 45, 2018 Том 44, 2017 Том 43, 2016 Том 42, 2015 Том 41, 2014 Том 40, 2013 Том 39, 2012 Том 38, 2011 Том 37, 2010 Том 36, 2009 Том 35, 2008 Том 34, 2007 Том 33, 2006 Том 32, 2005 Том 31, 2004 Том 30, 2003 Том 29, 2002 Том 28, 2001 Том 27, 2000 Том 26, 1999 Том 25, 1998 Том 24, 1997 Том 23, 1996 Том 22, 1995

International Journal of Fluid Mechanics Research

DOI: 10.1615/InterJFluidMechRes.v24.i4-6.240
pages 684-693

Entrained Water Atomization Experiments and its Size Measurements Using Optical Measurement Techniques

M. R. Ayob
Mechanical Engineering Faculty, University of Technology, Johor Baru, Malaysia
Colin J. Bates
Cardiff School of Engineering Cardiff University, PO Box 685 Cardiff CF24 3TA, UK

Краткое описание

This paper describes water entrainment measurements for twin-fluid atomization of air and water, for annular flow based upon a hydrodynamic development length of 228 with a tube diameter of 32 mm. The water and air flowrates considered were in the range 12.5−92.92 kg/(m2·s) and 25.43−82.21 kg/(m2·s) respectively. The data has been compared with previous results gathered by Sheriff (1993) and Teixeira (1987). This comparison shows a significant difference in entrainment flowrates, especially for the lower gas flow rates. At higher gas flowrates the entrained water data is in much closer agreement, for the lower water mass flowrate. These differences may be due to the different experimental rig configurations, although the entrainment and breakup mechanisms would not indicate otherwise. The water atomization generated a wide range of droplet size. Theses droplet sizes were measured using advanced optical techniques based on light scattering and light diffraction concepts. Phase Doppler Anemometry (PDA) provides both the diameter and velocity of individual droplets, whilst the Malvern instrument gives an ensemble droplet diameter. Results based on both diameters will be presented in terms of number mean diameter (D10) and Sauter mean diameter (D32). As the gas mass flow-rate increases both D10 and D32 decrease as expected. The ratio of D32 to D10 is observed to be 1.5. Droplet measurements using PDA system were performed using a collection scattering angle of 70°, using both a 300 mW and a 2 W argon-ion laser. The results show the influence of laser power and also demonstrate a wider droplet range and appreciable difference, of up to 100%, in comparison with The Malvern measurements. The latter measurements take account of the influence of vignetting which is an inherent feature associated with this type of measurement facility. Special design of optical head employed in order to reduce this effect. Since modem CFD simulations rely upon accurate input data it is important to highlight these experimental differences, early droplet diffraction measurement found in the published literature make no allowance for the influence of vignetting.


Articles with similar content:

COMPARISON AND CROSS-VALIDATION OF OPTICAL TECHNIQUES IN DIFFERENT SWIRL SPRAY REGIMES
Atomization and Sprays, Vol.23, 2013, issue 8
Ranganathan Kumar, Joshua Lee, Saptarshi Basu
An Experimental Study on Droplet Interactions
International Journal of Fluid Mechanics Research, Vol.24, 1997, issue 4-6
J. F. Virepinte, G. Lavergne, Y. Biscos, O. Adam
LARGE EDDY SIMULATION OF DROPLET STOKES NUMBER EFFECTS ON MIXTURE QUALITY IN FUEL SPRAYS
Atomization and Sprays, Vol.20, 2010, issue 5
Harri Hillamo, Martti Larmi, M. Nuutinen, Ossi Kaario, Laszlo Fuchs, Ville Vuorinen
DIESEL FUEL SPRAY DROPLET SIZES AND VOLUME FRACTIONS FROM THE REGION 25 MM BELOW THE ORIFICE
Atomization and Sprays, Vol.13, 2003, issue 1
Terry Parker, Jennifer Labs
STRUCTURE OF VAPORIZING PRESSURE ATOMIZED SPRAYS
Atomization and Sprays, Vol.3, 1993, issue 3
G. Scott Samuelsen, Vincent McDonell