Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
International Journal of Fluid Mechanics Research
ESCI SJR: 0.206 SNIP: 0.446 CiteScore™: 0.5

ISSN Печать: 2152-5102
ISSN Онлайн: 2152-5110

Выпуски:
Том 46, 2019 Том 45, 2018 Том 44, 2017 Том 43, 2016 Том 42, 2015 Том 41, 2014 Том 40, 2013 Том 39, 2012 Том 38, 2011 Том 37, 2010 Том 36, 2009 Том 35, 2008 Том 34, 2007 Том 33, 2006 Том 32, 2005 Том 31, 2004 Том 30, 2003 Том 29, 2002 Том 28, 2001 Том 27, 2000 Том 26, 1999 Том 25, 1998 Том 24, 1997 Том 23, 1996 Том 22, 1995

International Journal of Fluid Mechanics Research

DOI: 10.1615/InterJFluidMechRes.v24.i4-6.150
pages 590-598

Measurement of the Extensional Properties of Polyacrilamide Solutions Using the Falling Droplet Technique

Adel Mansour
Spray Systems Technology Center, Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, Pennsylvania, USA
Norman Chigier
Department of Mechanical Engineering Carnegie-Mellon University, Pittsburgh, PA 15213-3890

Краткое описание

The falling droplet technique is used to determine the extensional properties of very dilute and semi-dilute polymeric solutions. Nine different aqueous solutions of Polyacrilamide E10 were tested spanning a wide range of polymer concentration. The extensional viscosity for all solutions was found to be orders of magnitude larger than the shear viscosity. The extensional viscosity increases rapidly with time after the start of stretching. It was also shown that there is a linear relationship between the stress and the strain in the fluid filament, indicating that the fluid behaves like an elastic solid. The modulus of elasticity of the fluid was found to increase rapidly at low polymer concentrations, up to 0.1%, with no subsequent increase at higher concentrations. The stretch rate was found to be a decreasing function of polymer concentration. The stretch rate determined from the measurement of filament diameter was found to be greater than that determined by measurement of filament length. The spread between the two experimentally determined stretch rates was found to decrease with polymer concentration. This discrepancy is due to the small forward flow from the filament into the droplets and the back flow from the filament into the filament attachment region due to capillary action.


Articles with similar content:

MEASUREMENT OF EXTENSIONAL VISCOSITY OF POLYMER SOLUTIONS AND ITS EFFECTS ON ATOMIZATION FROM A SPRAY NOZZLE
Atomization and Sprays, Vol.6, 1996, issue 2
R. W. Dexter
ANALYTICAL SOLUTION OF UNSTEADY MHD PERIODIC FLOW OF A NON-NEWTONIAN FLUID THROUGH A POROUS CHANNEL
Journal of Porous Media, Vol.15, 2012, issue 11
A. Taklifi, A. Aliabadi
INFLUENCE OF RHEOLOGICAL PROPERTY CHANGES ON FRICTION AND CONVECTIVE HEAT TRANSFER IN A VISCOELASTIC POLYACRYLAMIDE SOLUTION
International Heat Transfer Conference 6, Vol.5, 1978, issue
Т. T. Tung, K. S. Ng , James P. Hartnett
INFLUENCE OF LIQUID VISCOSITY ON PRESSURE-SWIRL ATOMIZER PERFORMANCE
Atomization and Sprays, Vol.1, 1991, issue 1
Arthur H. Lefebvre, S. Kevin Chen, J. Rollbuhler
PREDICTION OF THE RETENTION VOLUME OF SEDIMENT DURING WATER-BASED SEDIMENT INJECTION
Journal of Porous Media, Vol.16, 2013, issue 6
Tadashi Hibino, Narong Touch