Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Journal of Flow Visualization and Image Processing
SJR: 0.161 SNIP: 0.312 CiteScore™: 0.1

ISSN Печать: 1065-3090
ISSN Онлайн: 1940-4336

Выпуски:
Том 26, 2019 Том 25, 2018 Том 24, 2017 Том 23, 2016 Том 22, 2015 Том 21, 2014 Том 20, 2013 Том 19, 2012 Том 18, 2011 Том 17, 2010 Том 16, 2009 Том 15, 2008 Том 14, 2007 Том 13, 2006 Том 12, 2005 Том 11, 2004 Том 10, 2003 Том 9, 2002 Том 8, 2001 Том 7, 2000 Том 6, 1999 Том 5, 1998 Том 4, 1997 Том 3, 1996 Том 2, 1995 Том 1, 1993

Journal of Flow Visualization and Image Processing

DOI: 10.1615/JFlowVisImageProc.v14.i1.50
pages 67-84

TIME-RESOLVED STEREO PIV MEASUREMENT OF PULSATILE FLOW IN AN ARTERY MODEL

M. Oishi
Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-Ku, Tokyo, 153-8505, Japan
M. Oshima
Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-Ku, Tokyo, 153-8505, Japan
Y. Bando
Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-Ku, Tokyo, 153-8505, Japan
T. Kobayashi
University of Tokyo; and Japan Automobile Research Institute, 2530 Karima, Tsukuba-city, Ibaraki, 305-0822, Japan

Краткое описание

This study investigated the behavior of pulsatile blood flow in a curved pipe that simulates the internal carotid artery (ICA), which is a common location for an aneurysm. Since complex secondary flow arises due to the curvature of artery, particle image velocimetry (PIV) was applied to obtain detailed flow information from in vitro experiments. However, blood flow in arteries is pulsatile and time-resolution of conventional PIV is not adequate for capturing the transient behavior of pulsatile flow. Thus, time-resolved PIV, which consists of high-speed cameras and high repetition rate lasers, was applied to measure unsteady flow. This new measurement method can provide superior resolution in space and in time.
Here, we demonstrate an improvement in resolution in space from a two-dimensional PIV system as compared to a stereo PIV system. To perform stereo calibration within a narrow and complex measurement area, we developed a non-invasive stereo calibration technique using lasers.
Stereo time-resolved PIV measurement allows the observation of two-dimensional, three-component transient flow structure. Pairs of secondary-flow vortices have different momentum and affect one other significantly. Flow characteristics at the systole phase are drastically different from those at the diastole phase, even with a similar Reynolds number.