Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Heat Transfer Research
Импакт фактор: 0.404 5-летний Импакт фактор: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Печать: 1064-2285
ISSN Онлайн: 2162-6561

Выпуски:
Том 51, 2020 Том 50, 2019 Том 49, 2018 Том 48, 2017 Том 47, 2016 Том 46, 2015 Том 45, 2014 Том 44, 2013 Том 43, 2012 Том 42, 2011 Том 41, 2010 Том 40, 2009 Том 39, 2008 Том 38, 2007 Том 37, 2006 Том 36, 2005 Том 35, 2004 Том 34, 2003 Том 33, 2002 Том 32, 2001 Том 31, 2000 Том 30, 1999 Том 29, 1998 Том 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.v40.i6.50
pages 571-588

A Comparative Study on Flow Boiling Heat-Transfer Coefficient of R-134a and R-134a/R-290/R-600a Refrigerant Mixture

Balakrishnan Raja
IIITD&M Kancheepuram
Palanisamy Balachander
R&AC Division, Department of Mechanical Engineering, College of Engineering, Guindy, Anna University, Chennai − 600 025, India
Dhasan Mohan Lal
R&AC Division, Department of Mechanical Engineering, College of Engineering, Guindy, Anna University, Chennai − 600 025, India
Rajagopal Saravanan
R&AC Division, Department of Mechanical Engineering, College of Engineering, Guindy, Anna University, Chennai-600 025, India

Краткое описание

The flow boiling heat-transfer coefficients of R-134a and R-134a/R-290/R-600a zeotropic refrigerant mixture were experimentally measured in a smooth horizontal tube of a 9.52-mm diameter. The values were compared for similar working pressure, reduced pressure, and liquid entry saturation temperature. The tests were conducted under varied heat flux conditions for stratified flow patterns; the conditions are found in evaporators of refrigerators and deep freezers. The varied heat flux conditions were imposed on the test fluids using a coaxial counter-current heat exchanger test section. The heat-transfer coefficients of the R-134a/R-290/R-600a refrigerant mixture were found to be better than those of R-134a under the same pressure and reduced pressure. However, under the same liquid entry temperature, the values of R-134a were found to be higher at low vapor qualities and lower at higher vapor qualities.


Articles with similar content:

EFFECT OF INLET TUBE SPACING ON FRICTION FACTORS IN MULTIPLE CIRCULAR TUBES IN THE TRANSITIONAL FLOW REGIME
International Heat Transfer Conference 16, Vol.9, 2018, issue
Josua Petrus Meyer, Marilize Everts
EXPERIMENTAL COMPARISON OF THE HEAT TRANSFER PERFORMANCE OF MICROCHANNEL GEOMETRIES
Heat Pipe Science and Technology, An International Journal, Vol.2, 2011, issue 1-4
Yigit Ata Agartan, Almila G. Yazicioglu
COMPARISON OF EVAPORATION PRESSURE DROP CHARACTERISTICS IN HORIZONTAL THREE-DIMENSIONAL ENHANCED TUBES
International Heat Transfer Conference 16, Vol.14, 2018, issue
Yan He, S.A. Sherif, Xiang Ma, Wei Li, Weiyu Tang
CONDENSATION PRESSURE DROP CHARACTERISTICS OF R410A INSIDE HORIZONTAL THREE-DIMENSIONAL ENHANCED TUBES
International Heat Transfer Conference 16, Vol.7, 2018, issue
Yan He, Zhi-chuan Sun, Wei Chen, Wei Li, Ruiheng Guo
Two-Phase Dispersed Flow Heat Transfer Augmented By Twisted Tapes
Journal of Enhanced Heat Transfer, Vol.1, 1994, issue 4
W. J. Minkowycz, M.-S. Wu, P. Papadopoulos, J. Harty, M. N. Hamouden, D. M. France