Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Heat Transfer Research
Импакт фактор: 0.404 5-летний Импакт фактор: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Печать: 1064-2285
ISSN Онлайн: 2162-6561

Выпуски:
Том 50, 2019 Том 49, 2018 Том 48, 2017 Том 47, 2016 Том 46, 2015 Том 45, 2014 Том 44, 2013 Том 43, 2012 Том 42, 2011 Том 41, 2010 Том 40, 2009 Том 39, 2008 Том 38, 2007 Том 37, 2006 Том 36, 2005 Том 35, 2004 Том 34, 2003 Том 33, 2002 Том 32, 2001 Том 31, 2000 Том 30, 1999 Том 29, 1998 Том 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2014006892
pages 311-332

EXPERIMENTAL INVESTIGATION OF A SMALL-SCALE THERMALLY DRIVEN PRESSURIZED ADSORPTION CHILLER

Wai Soong Loh
Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117576
Azhar Bin Ismail
Water Desalination and Reuse Center, 4700 King Abdullah, University of Science and Technology (KAUST), Twuwal 23955-6900
Kim Choon Ng
Department of Mechanical Engineering, National University of Singapore; Water Desalination and Reuse Center, 4700 King Abdullah, University of Science and Technology (KAUST), Twuwal 23955-6900
Won Gee Chun
Department of Nuclear and Energy, Jeju National University, Jeju, Korea

Краткое описание

This paper describes the successful operation of an adsorption cycle in a miniaturized adsorption chiller (AD). The experiments show that the bench-scale pressurized adsorption chiller (PAC) has been successfully designed, commissioned, and tested. Experimental results at various heat fluxes, half-cycle operation time intervals, and a cooling load of up to 24 W are also presented. A COP ranging from 0.05 to 0.15 is achieved depending on the parameters of the experimental conditions. Most importantly, the cooling performance of the PAC is achieved at a low encasement temperature that is below ambient. Besides having a high cooling density, the PAC has almost no major moving parts except for the fan of the condenser and it permits quiet operation as compared to other active coolers.


Articles with similar content:

Design and Performance Analysis of an Advanced Thermal Battery for Electric Vehicle Climate Control
International Heat Transfer Conference 15, Vol.5, 2014, issue
Sungwoo Yang, Ian S. McKay, Evelyn N. Wang, Hyunho Kim, Shankar Narayanan, Xiansen Li
AN EXPERIMENTAL STUDY OF PLASTIC HEAT EXCHANGERS APPLICABLE FOR DEHUMIDIFICATION
International Heat Transfer Conference 16, Vol.13, 2018, issue
Ming-Chang Lu, Mohammed Amer, Chi-Chuan Wang, Miao-Ru Chen
EXPERIMENTAL STUDY OF HEAT TRANSFER AND PRESSURE DROP IN A MULTISTRING BASED DIRECT CONTACT HEAT EXCHANGER
International Heat Transfer Conference 16, Vol.20, 2018, issue
Abolfazl Sadeghpour, Zezhi Zeng, Y. Sungtaek Ju
Experimental Investigation of a Small Capillary Pumped Loop Subjected to Antigravity
Journal of Enhanced Heat Transfer, Vol.14, 2007, issue 3
Qiang Li, Jiyu Qian, Yimin Xuan
A NOVEL DESIGN OF A LOW COST, ROBUST, EFFICIENT AND DYNAMIC ELECTROLYSER OPTIMISED FOR FLUCTUATING AND INTERMITTENT RENEWABLE ENERGY POWERED OPERATION
HYSYDAYS
1st World Congress of Young Scientists on Hydrogen Energy Systems, Vol.0, 2005, issue
Simon Watson , Amitava Roy, David Infield