DOI: 10.1615/HeatTransRes.v43.i5.30
pages 425-442

INTERFACIAL SHEAR OF CO-CURRENT STEAM−WATER FLOW ESTIMATION − II. ENHANCED SINGLE-PHASE FLUENT MODEL IN CONJUNCTION WITH MEASURED PROFILES OF STEAM VELOCITY AND LONGITUDINAL WATER TEMPERATURE

Stasys Gasiunas
Lithuanian Energy Institute, 3 Breslaujos str., LT-3035 Kaunas, Lithuania
Marijus Seporaitis
Lithuanian Energy Institute, 3 Breslaujos g., Kaunas, LITHUANIA, LT-44403
Benediktas B. Cesna
Lithuanian Energy Institute, Kaunas, Lithuania
Mindaugas Valincius
Lithuanian Energy Institute, 3 Breslaujos str., LT-3035 Kaunas, Lithuania
Raimondas Pabarcius
Lithuanian Energy Institute, 3 Breslaujos str., LT-3035 Kaunas, Lithuania
Darius Laurinavicius
Lithuanian Energy Institute, Kaunas, Lithuania

Краткое описание

The results of condensation implosion tests (Almenas et al., 2006) and slug flow occurrence (Chun and Yu, 2000) lead to the conclusion that condensation may have some serious impact on steam−liquid interface stability. To explore this in detail a special test facility was constructed and the FLUENT 3D model (single phase with condensation simulation) is developed at the Lithuanian Energy Institute. The following investigation seeks to determine the condensation influence on the stability of a horizontal two-phase flow interface and the overall purpose of the program is to employ transitional behaviors with positive feedback between momentum and energy transfer in real systems.
This paper presents the experimental test facility developed at LEI and the methodology of the experiments whose results were employed to adapt and verify the FLUENT 3D model. Preliminary results of modeling show that both the boundary-layer thickness and interfacial shear strongly depend on condensation.


Articles with similar content:

Interfacial Shear of Co-Current Steam−Water Flow Estimation − I. Single-Phase FLUENT Model in Conjunction with Measured Total Increment of Water Temperature and Steam Velocity Profile Data
Heat Transfer Research, Vol.42, 2011, issue 7
Benediktas B. Cesna, Darius Laurinavicius, Stasys Gasiunas, Mindaugas Valincius, Marijus Seporaitis, Raimondas Pabarcius
INVESTIGATION OF STRATIFIED WAVY TWO-PHASE FLOW CHARACTERISTICS
International Heat Transfer Conference 13, Vol.0, 2006, issue
Stasys Gasiunas, Marijus Seporaitis, Raimondas Pabarcius
Development of a pulser for the controlled initiation of condensation implosion events
International Heat Transfer Conference 12, Vol.42, 2002, issue
Kazys Almenas, Marijus Seporaitis, Raimondas Pabarcius
COMPARISON OF PERFORMANCE OF DIFFERENT MULTIPHASE MODELS IN PREDICTING STRATIFIED FLOW
Computational Thermal Sciences: An International Journal, Vol.9, 2017, issue 6
Satish Kumar Dewangan, Santosh Kumar Senapati
SIMULATION OF NATURAL CIRCULATION FLOW DURING POWER MANEUVERING IN MASLWR TEST FACILITY WITH COMPUTER CODE RELAP-5/MOD3.2
Proceedings of the 24th National and 2nd International ISHMT-ASTFE Heat and Mass Transfer Conference (IHMTC-2017), Vol.0, 2017, issue
M. Singhal, T.A. Khan, Chandana P, Ashutosh Dixit, S. Hajela, N. Kumar, S.K. Yadav