Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Heat Transfer Research
Импакт фактор: 0.404 5-летний Импакт фактор: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Печать: 1064-2285
ISSN Онлайн: 2162-6561

Выпуски:
Том 50, 2019 Том 49, 2018 Том 48, 2017 Том 47, 2016 Том 46, 2015 Том 45, 2014 Том 44, 2013 Том 43, 2012 Том 42, 2011 Том 41, 2010 Том 40, 2009 Том 39, 2008 Том 38, 2007 Том 37, 2006 Том 36, 2005 Том 35, 2004 Том 34, 2003 Том 33, 2002 Том 32, 2001 Том 31, 2000 Том 30, 1999 Том 29, 1998 Том 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2016008323
pages 23-34

MODELING THE INFLUENCE OF INCLINATION ANGLE ON NATURAL CONVECTION AROUND AN EVACUATED TUBE SOLAR COLLECTOR

Dardan Klimenta
Faculty of Technical Sciences, University of Pristina in Kosovska Mitrovica, Kneza Milosa 7, Kosovska Mitrovica 38220, Serbia

Краткое описание

The main purpose of this paper is to propose a procedure for modeling heat transfer by natural convection for both laminar and turbulent flows around an evacuated tube collector at inclination angles of 0−90°. Using the experimental results obtained by Heo and Chung (2012) for different cylinders and inclinations, the heat transfer correlations based on the fundamental dimensionless number for natural convection have been derived. Their experiments included measurements for solid circular cylinders having diameters of 0.01, 0.034, and 0.067 m, and lengths of 0.1, 0.25, and 0.45 m, as well as for a Prandtl number of 2094 in either laminar or turbulent conditions. Introducing the correlations based on the fundamental dimensionless number for natural convection, the studies performed on inclined cylinders were generalized for the whole range of Prandtl numbers. A modified Nusselt number, which represents the mean of the heat transfer correlations based on the cylinder diameter and on the cylinder length, was introduced and applied to estimate the heat transfer coefficients for natural convection on the outer surface of an evacuated tube collector surrounded by air. The results obtained by applying the proposed correlations were also compared to the results obtained using existing ones for various Prandtl numbers.


Articles with similar content:

ANALYSIS AND GENERALIZATION OF THE EXPERIMENTAL DATA ON HEAT TRANSFER IN STAGGERED BUNDLES OF FLAT-OVAL TUBES
International Journal of Energy for a Clean Environment, Vol.18, 2017, issue 3
Aleksandr V. Baranyuk, A. M. Terekh, V. A. Rogachov, V. A. Kondratiuk, A. I. Rudenko
ANALYTICAL DETERMINATION OF THE PERMEABILITY FOR SLOW FLOW PAST PERIODIC ARRAYS OF CYLINDERS WITH DIFFERENT CROSS SECTIONS
Journal of Porous Media, Vol.15, 2012, issue 11
H. Basci, O. Cetiner, D. Erdem, H. Acar, A. Cihat Baytas
NATURAL CONVECTION HEAT TRANSFER IN A HORIZONTAL CONCENTRIC ELLIPTIC ANNULUS CONTAINING SATURATED POROUS MEDIA
Journal of Porous Media, Vol.15, 2012, issue 6
Ramadan Y. Sakr, Nabil S. Berbish
TURBULENT FILM EVAPORATION ON AND CONDENSATION IN HORIZONTAL ELLIPTICAL CONDUITS
International Heat Transfer Conference 6, Vol.4, 1978, issue
David Moalem-Maron , S. Esaki , Raphael Semiat, Samuel Sideman
Effects of Tube Diameter and Tubeside Fin Geometry on the Heat Transfer Performance of Air-Cooled Condensers
Journal of Enhanced Heat Transfer, Vol.8, 2001, issue 5
Hiroshi Honda, Hua Sheng Wang