Доступ предоставлен для: Guest
Портал Begell Электронная Бибилиотека e-Книги Журналы Справочники и Сборники статей Коллекции
Critical Reviews™ in Therapeutic Drug Carrier Systems
Импакт фактор: 2.9 5-летний Импакт фактор: 3.72 SJR: 0.573 SNIP: 0.551 CiteScore™: 2.43

ISSN Печать: 0743-4863
ISSN Онлайн: 2162-660X

Выпуски:
Том 36, 2019 Том 35, 2018 Том 34, 2017 Том 33, 2016 Том 32, 2015 Том 31, 2014 Том 30, 2013 Том 29, 2012 Том 28, 2011 Том 27, 2010 Том 26, 2009 Том 25, 2008 Том 24, 2007 Том 23, 2006 Том 22, 2005 Том 21, 2004 Том 20, 2003 Том 19, 2002 Том 18, 2001 Том 17, 2000 Том 16, 1999 Том 15, 1998 Том 14, 1997 Том 13, 1996 Том 12, 1995

Critical Reviews™ in Therapeutic Drug Carrier Systems

DOI: 10.1615/CritRevTherDrugCarrierSyst.v22.i1.10
pages 1-26

Therapy Considerations in Drug-Eluting Stents

Jeffrey T. Ellis
Deborah L. Kilpatrick
Paul Macke Consigny
Department of Radiology, Suite 4200 Gibbon, Thomas Jefferson University Hospital, Thomas Jefferson University, 111 South 11th St., Philadelphia, PA 19107; and Department of Physiology, Jefferson Medical College, Philadelphia, PA 19107
Santosh Prabhu
Syed F. A. Hossainy
Guidant Corporation, 3200 Lakeside Drive, Mailstop S-238, Santa Clara CA 95054-2807, USA

Краткое описание

Approximately 12 million Americans have coronary artery disease, and almost one in five deaths in the United States can be attributed to this disease. In addition, 1.2 million Americans undergo cardiac catheterization and over one-half million receive a percutaneous coronary intervention such as balloon angioplasty, atherectomy, or stent implantation annually. This article will provide an overview of (1) atherosclerosis, the progressive disease which can lead to thrombotic events and/or the development of hemodynamically significant coronary artery lesions; (2) restenosis, the reappearance of significant lesions after coronary interventions such as stent placement; and (3) drugeluting stents, the devices which, by using appropriate polymers to elute the appropriate drug with the appropriate pharmacokinetics, have almost completely eliminated restenosis.


Articles with similar content:

Analysis of Sixty-Two Explanted Liotta Bioprostheses: Biocompatibility, Biofunctionality, and Biodurability Issues
Journal of Long-Term Effects of Medical Implants, Vol.18, 2008, issue 2
Iradj Gandjbakhch, Robert Guidoin, Xiaoyan Deng, Randolph Guzman, Tieying Yin, Georgi R. Marinov, Hongbo Zhang, Tomas Francisco Cianciulli, Patrick Mathieu, Alain Pavie, Ze Zhang, Andre-Pierre Legrand, Jorge Jordana
Long-Term Evaluation of Laser-Treated Silicone (LTS) Membrane as a Pericardial Substitute: In Vivo Study
Journal of Long-Term Effects of Medical Implants, Vol.15, 2005, issue 4
Hosein Ahamadi, Hamid Mirzadeh, Saeid Amanpour, Mohammad Ali Mohagheghi, Shahram Rabbani
Histologic and Hemodynamic Effects of Endosaccular Platinum Coils for Intracranial Aneurysms
Journal of Long-Term Effects of Medical Implants, Vol.14, 2004, issue 3
Colin P. Derdeyn, DeWitte T. Cross III, Ralph G. Dacey Jr., Alex M. Barrocas, Christopher J. Moran
Hydrocephalus and Ventriculoperitoneal Shunts: Modes of Failure and Opportunities for Improvement
Critical Reviews™ in Biomedical Engineering, Vol.44, 2016, issue 1-2
Corin Williams, Julianne Jorgensen, Alisha Sarang-Sieminski
Radiographic Evaluation of Bone-Level Implants with Wound Dehiscence between the First- and Second-Stage Surgeries
Journal of Long-Term Effects of Medical Implants, Vol.26, 2016, issue 3
Mohsen Bidgoli, Javad Faradmal, Sara Soheilifar, Erfan Abbasi Atibeh