Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
International Journal of Fluid Mechanics Research
ESCI SJR: 0.206 SNIP: 0.446 CiteScore™: 0.5

ISSN Imprimir: 2152-5102
ISSN On-line: 2152-5110

Volumes:
Volume 46, 2019 Volume 45, 2018 Volume 44, 2017 Volume 43, 2016 Volume 42, 2015 Volume 41, 2014 Volume 40, 2013 Volume 39, 2012 Volume 38, 2011 Volume 37, 2010 Volume 36, 2009 Volume 35, 2008 Volume 34, 2007 Volume 33, 2006 Volume 32, 2005 Volume 31, 2004 Volume 30, 2003 Volume 29, 2002 Volume 28, 2001 Volume 27, 2000 Volume 26, 1999 Volume 25, 1998 Volume 24, 1997 Volume 23, 1996 Volume 22, 1995

International Journal of Fluid Mechanics Research

DOI: 10.1615/InterJFluidMechRes.v25.i4-6.50
pages 506-519

Effects of Exfiltration on Moisture and Frost Accumulation in a Fibrous Insulation

Y. -X. Tao
Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, Canada
D. R. Mitchell
Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, Canada
Robert W. Besant
Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, Canada

RESUMO

Experiments were performed of heat and moisture transport, coupled with air exfiltration, through a glass-fiber slab. The measured data, showing a coupling effect of air movement with moisture and frost accumulation, are compared to a numerical model. A constant airflow, at a rate compatible to typical building envelope air exfiltration rates, passes through the test slab from the warm side of the slab (at a room temperature and for various humidity levels) to its cold side (below the triple point of water). Through temperature, heat flux and moisture accumulation measurements, the increase in heat loss due to the transport of moisture by moist air is demonstrated. A one-dimensional, numerical model, including convection and vapor diffusion in porous media, is developed to simulate the process under the test, conditions. Comparisons between the experimental and numerical results are favorable. It is shown that the increase in moisture accumulation under frosting condition could be an order of magnitude higher than for the temperature range above freezing. The conduction heal, loss can be up to 300% higher with air exfiltration, depending on the exfiltration rates, as compared to the moisture diffusion-only process (i.e., no exfiltration) under the same temperature boundary conditions.


Articles with similar content:

HEAT STORAGE ANALYSIS OF ENERGY PILES WITH SPIRAL-TUBE HEAT EXCHANGER BASED ON A PRACTICAL AXISYMMETRIC MODEL
International Heat Transfer Conference 16, Vol.20, 2018, issue
Baoming Chen, Qiang Zhao, Maocheng Tian, Fang Liu
MODELING AND EXPERIMENTAL STUDIES FOR THERMAL PERFORMANCE OF A GROUND HEAT STORAGE SYSTEM INTEGRATED WITH A GREENHOUSE
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2009, issue
Mejdi Hazami, Meriem Lazaar, Sami Kooli, Ali Belghith, Abdelhamid Farhat
A NUMERICAL STUDY OF DRYING AND PREHEATING OF FOOD IN A ROTARY DRYER WITH SUPERHEATED STEAM AND AIR AS THE DRYING MEDIA
International Heat Transfer Conference 16, Vol.6, 2018, issue
Atinder Pal Singh, Partha S. Ghoshdastidar
FROST FORMATION ON COOLED PARALLEL PLATES IN LAMINAR FORCED CONVECTION
International Heat Transfer Conference 11, Vol.20, 1998, issue
H. Beer, A. Luer
Characteristics of a Plate-Fin Heat Exchanger with Phase Change Materials
Journal of Enhanced Heat Transfer, Vol.2, 1995, issue 4
Masashi Okada