Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Heat Transfer Research
Fator do impacto: 0.404 FI de cinco anos: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN On-line: 2162-6561

Volumes:
Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2018020698
pages 183-194

EFFECTS OF SCALING ON PRESSURE DROP AND TUBE WALL TEMPERATURE OF STEAM INJECTION BOILERS REUSING OIL FIELD PRODUCED WATER

Wei Zhang
College of Pipeline and Civil Engineering, China University of Petroleum (East China), Qingdao, Shandong, P.R. China, 266580
Bin Li
College of Pipeline and Civil Engineering, China University of Petroleum (East China), Qingdao, Shandong, P.R. China, 266580
Liang Gong
Department of Energy and Power Engineering, China University of Petroleum (East China), 66 West Changjiang Rd. Huangdao District, Qingdao 266580, PR. China

RESUMO

Reusing produced water in steam boilers can save fresh water. However, because of the strong scaling characteristics of produced water, the operation condition of a steam injection boiler varies after reusing the produced water. A computing program is developed to theoretically study the effects of scaling on the pressure drop and the tube wall temperature of a steam injection boiler, and to finally find a key parameter used to monitor the operation safety of a steam injection boiler. The calculation results show that the thermal conductivity of water scale has almost no effect on the pressure drop and that the flow rate has a small effect on the wall temperature. The pressure drop is increased with increase of the scale thickness and flow rate and with decrease of the feed water pressure. While the wall temperature increases when the water scale thickness and feed water pressure increase, the thermal conductivity of water scale decreases. The maximal allowable pressure drop as a key parameter used to guide the boiler cleaning is obtained in this paper. It is not constant but depends on the thermal conductivity of water scale, the feed water pressure, and the flow rate. Once the pressure drop reaches the allowable value, the water scale must be removed by chemical cleaning to ensure the safe operation of a steam injection boiler.


Articles with similar content:

EFFECT OF THERMAL−HYDRAULIC PARAMETERS ON ENTROPY GENERATION IN A BOILING CHANNEL
Multiphase Science and Technology, Vol.26, 2014, issue 4
Saeed Talebi
Experience with Infrared Measurements in Mixed Air-Steam and Water Droplet Flow
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 1985, issue
F. Sakkal, Jurgen Vollbrandt
EXPERIMENTAL INVESTIGATION OF WATER VAPORIZATION AND ITS INDUCED FORMATION DAMAGE ASSOCIATED WITH UNDERGROUND GAS STORAGE
Journal of Porous Media, Vol.16, 2013, issue 2
Saeed Abbasi, Abbas Shahrabadi, Mohammad Saadat, Hassan Golghanddashti
PERFORMANCE TEST OF THE 1025 T/H BOILER UNIT IN WUJIN THERMAL POWER PLANT
Energy and Environment, 1995, Vol.0, 1995, issue
YouKang Ge
THE STUDY ON THE DISTRIBUTION LAW OF INTERWELL PRESSURE GRADIENT CONSIDERING THE INFLUENCE OF PROFILE CONTROL AND WATER SHUTOFF
Journal of Porous Media, Vol.21, 2018, issue 3
Qiang Fu, Shuoliang Wang, Zhimin Du