Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Heat Transfer Research
Fator do impacto: 0.404 FI de cinco anos: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN On-line: 2162-6561

Volumes:
Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.v35.i12.120
7 pages

Structure of a Vapor-Water Flow and Characteristic Features of Its Separation in Large-Diameter Channels

S. G. Kalyakin
State Scientific Center of the Russian Federation "A. I. Leipunskii Physical-Power Engineering Institute," Obninsk, Russia
YU. V. Klimanova
State Scientific Center of the Russian Federation "A. I. Leipunskii Physical-Power Engineering Institute," Obninsk, Russia
O. V. Remizov
State Scientific Center of Russian Federation - "A. I. Leipunskii Physico-Energetical Institute" Obninsk, Russia
N. P. Serdun
State Scientific Center of the Russian Federation "A. I. Leipunskii Physical-Power Engineering Institute," Obninsk, Russia

RESUMO

The results pertaining to separation of a vapor-water flow and to its structure in large-diameter vertical channels are given. The tests were carried out at a pressure of 3.5 MPa and a vapor-water mixture flow rate of 10.0, 12.0, and 20.0 kg/sec, which corresponded to mass velocities in the test section of 750, 1000, and 1500 kg/m2·sec, respectively. Relative enthalpy changed from −0.05 to +0.2. The experiments have shown that the separation coefficient in a separating chamber is substantially higher than in similar channels of small diameter. This is caused by the fact that even at relative enthalpies equal to 0, an annular-dispersed vapor-water flow is formed in the inner pipe, whereas at higher values there is a ring structure with an actual void fraction equal to 0.9−0.95 in the major part of the section.


Articles with similar content:

EXPERIMENTAL STUDY ON TWO-PHASE SEPARATION IN A T-JUNCTION
Second Thermal and Fluids Engineering Conference, Vol.43, 2017, issue
Weicong Xu, Wen Su, Shuai Deng, Li Zhao, Nan Zheng
Distribution of Local Mass Transfer Coefficients on Walls of Complex-Shape Channels
Heat Transfer Research, Vol.32, 2001, issue 4-6
Vladimir Yu. Chekhovich, Nikolay I. Pecherkin, Bulat I. Nigmatulin
Experimental Study of Distribution of Local Coefficients of Mass Transfer on Walls of Complex-Shape Channels
Heat Transfer Research, Vol.33, 2002, issue 5&6
Vladimir Yu. Chekhovich, Nikolay I. Pecherkin, Bulat I. Nigmatulin
EXPERIMENTAL INVESTIGATION OF HEAT AND FLUID FLOW IN A TWO-PHASE HEAT TRANSPORT DEVICE WITH PARALLEL TUBES
Journal of Flow Visualization and Image Processing, Vol.18, 2011, issue 1
Akira Murata, Kaoru Iwamoto, Hiroshi Saito, Thanh-Long PHAN
EXPERIMENTAL INVESTIGATION OF FLOW BOILING HEAT TRANSFER BOUNDARY OF NITROGEN IN 1.2 MM VERTICAL MINI-CHANNEL
International Heat Transfer Conference 16, Vol.18, 2018, issue
Jianqiang Zhang, Beichen Zhang, Qinglian Li, Yuan Wang, Peng Zhang, Hongwei Jia