Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Heat Transfer Research
Fator do impacto: 0.404 FI de cinco anos: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN On-line: 2162-6561

Volumes:
Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2015010744
pages 259-275

COMPREHENSIVE EVALUATION OF POWER SUPPLY SYSTEMS FOR COMMERCIAL BUILDINGS BASED ON GRAY RELATIONAL ANALYSIS AND ANALYTIC HIERARCHY PROCESS

Qingqing Yong
Department of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China; Department of Electric Engineering, Shanghai Dianji Univeristy, Shanghai, 200120, China
mo yang
university of shanghai for science and technology
W. Lu
Department of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China
J. Chen
Department of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai, 200093, China

RESUMO

This study establishes a scientific, reasonable, and feasible comprehensive evaluation system for green building's power supply system design and implementation to achieve optimization of their thermal, environmental, and economic performance. Unlike traditional evaluation methods that use single index such as economic performance or exergy efficiency for the criterion, the proposed evaluation method takes annual revenue, exergy efficiency, CO2 emission, and system reliability as indices. This advanced comprehensive evaluation method is based on a combination of the method of the gray relational analysis (GRA) and the analytic hierarchy process (AHP) to assess the multiobjective performance of building's power supply systems. The method is applied to compare four kinds of the power supply system of a hospital to determine the optimal system. The result shows that the system which combines cooling, heating, and power supply systems (CCHP) adding solar photovoltaic (PV) panels has the best comprehensive performance when the capacitance of solar PV panels is large enough.


Articles with similar content:

REVIEW OF PHOTOVOLTAIC-THERMAL COLLECTORS: AN OVERVIEW OF THE POTENTIAL BEYOND EXPERIMENTAL TESTING
International Journal of Energy for a Clean Environment, Vol.18, 2017, issue 3
E. E. Anyanwu, Nnamdi V. Ogueke
AN AHP APPROACH FOR EVALUATING THE GEOTHERMAL HVAC APPLICATIONS
Energy and the Environment, 1999, Vol.0, 1998, issue
M. Eltez, A. Eltez, N. Morali
DEVELOPMENT POSSIBILITIES OF SMALL SCALE COGENERATION PLANTS IN EU AND LITHUANIA
ENERGETIKA, Vol.1, 2004, issue 4
Gerardas Zukauskas, Romualdas Skema, Feliksas Zinevicius
COST OPTIMIZATION FOR DATA CENTER COOLING SYSTEM WITH THERMAL RESISTANCE-BASED METHOD
International Heat Transfer Conference 16, Vol.20, 2018, issue
Rong-Huan Fu, Xing Zhang
Multi-objective Optimization for a Free-piston Vuilleumier Heat Pump Based on an Evolutionary Algorithm
3rd Thermal and Fluids Engineering Conference (TFEC), Vol.6, 2018, issue
Jon P. Longtin, Hanfei Chen, ChihChieh Lin