Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Heat Transfer Research
Fator do impacto: 0.404 FI de cinco anos: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN On-line: 2162-6561

Volumes:
Volume 51, 2020 Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.v42.i2.40
pages 143-164

Influence of Internal Cyclone Flow on Adiabatic Film Cooling Effectiveness

Andreas Lerch
Institute of Gas Turbines and Aerospace Propulsion, Technische Universität Darmstadt, 64287 Darmstadt, Germany
Heinz-Peter Schiffer
Institute of Gas Turbines and Aerospace Propulsion, Technische Universität Darmstadt, 64287 Darmstadt, Germany

RESUMO

The adiabatic film cooling effectiveness on the surface of a symmetrical blade model was measured for eight cylindrical, 59° inclined cooling holes. The holes were fed with different flow types using a cylindrical leading-edge channel. Two configurations were compared: on the one hand, a leading-edge channel flow without swirl (datum configuration), using a sharp-edged inlet; on the other hand, a new cyclone cooling configuration with a positive swirl. The experiments were carried out using the calibrated ammonia diazo technique. The blowing ratios were varied between 0.6 and 1.2, and the film cooling discharge was set to either 20% or 50%. For all these operation points, multiple experiments were conducted and combined using a weighting average method to produce a high full-range resolution. The lateral and area-averaged adiabatic effectiveness is presented up to 45D downstream of the cooling holes. The measurements show a higher area-averaged effectiveness immediately downstream of the cooling holes when using the cyclone cooling configuration. This is due to nonsymmetric flow structures inside the cooling holes. Further downstream, however, it decreases faster. With a low film cooling discharge and rising blowing ratios, these effects are more pronounced.


Articles with similar content:

INFLUENCE OF INTERNAL CYCLONE FLOW ON ADIABATIC FILM COOLING EFFECTIVENESS
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2009, issue
Heinz-Peter Schiffer, Andreas Lerch
EFFECTS OF HOLE GEOMETRY ON HEAT (MASS) TRANSFER AND FILM COOLING EFFECTIVENESS
International Heat Transfer Conference 11, Vol.18, 1998, issue
Dong Ho Rhee, Hyung-Hee Cho, Byunggu Kim
FILM COOLING EFFECT OF THE LEAKAGE THROUGH THE SEAM OF ADJACENT TURBINE BLADE PLATFORMS
International Heat Transfer Conference 13, Vol.0, 2006, issue
M. Y. Jabbari, E. J. Thor, Richard J. Goldstein
Effect of Gap Geometry on the Cooling Effectiveness of the Wheelspace Coolant Injection Upstream of a Row of Rotor Blades
Heat Transfer Research, Vol.41, 2010, issue 6
M. Papa, V. Srinivasan, Fabio Gori, Richard J. Goldstein
EFFECT OF GAP GEOMETRY ON THE COOLING EFFECTIVENESS OF THE WHEELSPACE COOLANT INJECTION UPSTREAM OF A ROW OF ROTOR BLADES
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2009, issue
M. Papa, V. Srinivasan, Fabio Gori, Richard J. Goldstein