Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Heat Transfer Research
Fator do impacto: 0.404 FI de cinco anos: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN On-line: 2162-6561

Volumes:
Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2014007549
pages 383-397

EXPERIMENTAL STUDY ON A TWO-STAGE LIQUID DESICCANT DEHUMIDIFICATION SYSTEM USING DUAL DESICCANT SOLUTIONS

Zhenqin Xiong
School of Mechanical Engineering, Shanghai Jiao Tong University
Ruzhu Wang
Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, 800 Dongchuan Road. Minhang District, Shanghai 200240, China
Yanjun Dai
Institute of Refrigeration and Cryogenics, Key Laboratory for Power Machinery and Engineering of M.O.E, Shanghai Jiao Tong University, Shanghai, 200240, China

RESUMO

A two-stage liquid desiccant dehumidification system using a lithium chloride (LiCl) solution and a calcium chloride (CaCl2) solution respectively in the first- and second-stage dehumidifier was proposed through numerical analysis and exergy analysis in the previous study and it is improved by two methods, i.e., the high concentration variance and predehumidification of CaCl2. To assess its dehumidification performance and the predehumidification effect of the first-stage dehumidifier using CaCl2, an experimental study is carried out with dehumidifiers of the size 300 mm × 250 mm × 300 mm packed with Celdeck material under three typical conditions, i.e., ARI standard outdoor conditions, ARI dry outdoor conditions, and the typical summer outdoor conditions in Shanghai. It is proved that the humidity ratio of air after two-stage dehumidification under the ARI standard outdoor conditions and ARI dry outdoor conditions meets the requirement of the ARI indoor conditions when the LiCl concentration is in the range of 40−35% and the initial concentration of CaCl2 is 40%. It is founded that the predehumidification of a CaCl2 solution is significant. It can handle 20−63% of the total moisture load in the case studied. A parametric analysis has also been made. The results indicate that the humidity ratio after dehumidification is mainly influenced by the air velocity and the desiccant concentration of LiCl solution. The dehumidification performance deteriorates when the desiccant solution flow rate is around 300−400 kg/h due to the poor distribution of desiccant solutions on the packing material. The moisture removed by the CaCl2 solution depends on its concentration and the air velocity.


Articles with similar content:

AN EXPERIMENTAL INVESTIGATION OF AN ADSORPTION ICE-MAKER DRIVEN BY PARABOLIC TROUGH COLLECTOR
Heat Transfer Research, Vol.46, 2015, issue 4
Liwei Wang, W. T. Xie, T. Yan, Cheng Li, X. Li, Ruzhu Wang, T. X. Li, M. Lin
Effects of Evaporative Cooling on the Performance of Dry-Cooled Natural-Gas Combined-Cycle (NGCC) Power Plants
3rd Thermal and Fluids Engineering Conference (TFEC), Vol.32, 2018, issue
Wei Zhong, Tao He, Sotirios Mamalis, Yaroslav Chudnovsky, Jon P. Longtin
FIELD TEST ON THE COOLING PERFORMANCE FOR HIGH LEVEL WATER COLLECTING WET COOLING TOWER UNDER CROSSWIND CONDITIONS
International Heat Transfer Conference 16, Vol.9, 2018, issue
Fengzhong Sun, Zhigang Dang, Ming Gao, Jian Zou, Yang Zhou
Simple and Reproducible Two-Stage Agitation Speed Control Strategy for Enhanced Triterpene Production by Lingzhi or Reishi Medicinal Mushrooms, Ganoderma lucidum ACCC G0119 (Higher Basidiomycetes) Based on Submerged Liquid Fermentation
International Journal of Medicinal Mushrooms, Vol.17, 2015, issue 12
Yan Yang, Fang Liu, Jing-Song Zhang, Chi-Chung Lin, Wei Jia, Jie Feng, Na Feng
NON-REGENERATIVE MULTI-STAGE AND REGENERATIVE MULTI-BED ADSORPTION CYCLES FOR LOW-TEMPERATURE WASTE HEAT RECOVERY
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Kim Choon Ng, Bidyut Baran Saha, Takao Kashiwagi, Hui Tong Chua, Atsushi Akisawa