Volumes:
Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2014007549
pages 383-397

EXPERIMENTAL STUDY ON A TWO-STAGE LIQUID DESICCANT DEHUMIDIFICATION SYSTEM USING DUAL DESICCANT SOLUTIONS

Zhenqin Xiong
School of Mechanical Engineering, Shanghai Jiao Tong University
R Z Wang
Shanghai Jiao Tong University
Yanjun Dai
Institute of Refrigeration and Cryogenics, Key Laboratory for Power Machinery and Engineering of M.O.E, Shanghai Jiao Tong University, Shanghai, 200240, China

RESUMO

A two-stage liquid desiccant dehumidification system using a lithium chloride (LiCl) solution and a calcium chloride (CaCl2) solution respectively in the first- and second-stage dehumidifier was proposed through numerical analysis and exergy analysis in the previous study and it is improved by two methods, i.e., the high concentration variance and predehumidification of CaCl2. To assess its dehumidification performance and the predehumidification effect of the first-stage dehumidifier using CaCl2, an experimental study is carried out with dehumidifiers of the size 300 mm × 250 mm × 300 mm packed with Celdeck material under three typical conditions, i.e., ARI standard outdoor conditions, ARI dry outdoor conditions, and the typical summer outdoor conditions in Shanghai. It is proved that the humidity ratio of air after two-stage dehumidification under the ARI standard outdoor conditions and ARI dry outdoor conditions meets the requirement of the ARI indoor conditions when the LiCl concentration is in the range of 40−35% and the initial concentration of CaCl2 is 40%. It is founded that the predehumidification of a CaCl2 solution is significant. It can handle 20−63% of the total moisture load in the case studied. A parametric analysis has also been made. The results indicate that the humidity ratio after dehumidification is mainly influenced by the air velocity and the desiccant concentration of LiCl solution. The dehumidification performance deteriorates when the desiccant solution flow rate is around 300−400 kg/h due to the poor distribution of desiccant solutions on the packing material. The moisture removed by the CaCl2 solution depends on its concentration and the air velocity.


Articles with similar content:

FORMATION OF PYROPHORIC IRON PARTICLES BY H2 REDUCTION OF OXALATE AND OXIDES
International Journal of Energetic Materials and Chemical Propulsion, Vol.7, 2008, issue 2
Rajesh V. Shende, Deepak Kapoor, Darold Martin, Zachary D. Doorenbos, Alok Vats, Jan A. Puszynski
PERFORMANCE COMPARISON OF ALUMINUM AND COPPER FINNED TUBE EVAPORATORS USED IN A RESIDENTIAL AIR-CONDITIONER
International Heat Transfer Conference 13, Vol.0, 2006, issue
W. Zhen, Jingchun Min, F. Gao, L. F. Shen
Seasonal Dynamics of Microbiological Cycle of Methane in the Water of Littoral Shallow Zones of the Rybinsk Reservoir
Hydrobiological Journal, Vol.43, 2007, issue 2
A. N. Dzyuban
DESIGN, CONSTRUCTION, AND TESTING OF A CYLINDRICAL SOLAR WATER HEATER
International Journal of Energy for a Clean Environment, Vol.10, 2009, issue 1-4
M. C. Njoku, E. E. Anyanwu, Nnamdi V. Ogueke
Effect of Electric Fields on Frosting Phenomenon
International Journal of Fluid Mechanics Research, Vol.25, 1998, issue 4-6
Akira Yabe, Ichiro Tanasawa, Tetsuo Munakata