Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2013006189
pages 665-686

TRIPLE TUBE AMMONIA EVAPORATOR DESIGN FOR DOMESTIC ABSORPTION REFRIGERATORS

Ahmed Mohammed Adham
Erbil Polytechnic University
Normah Mohd-Ghazali
Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, 81310 Skudai, Johor Barhru, Malaysia
Mikdam M. Saleh
Power Engineering Department, College of Engineering, University of Baghdad, Al‐Jadriya, Baghdad, Iraq
Robiah Ahmad
UTM Razak School of Engineering and Advanced Technology, Universiti Teknologi Malaysia International campus, 54100 Jalan Semarak, Kuala Lumpur, Malaysia

RESUMO

A usable concept for an ammonia evaporator in an absorption refrigerator based on a triple tube design is considered. The differential equations that describe the energy transfer between the ammonia refrigerant and the ammonia hydrogen gas mixture are utilized to simulate the thermal and hydrodynamic performances and hence to determine the operation of evaporator. This simulation procedure is used to determine the geometrical parameters of the evaporator, subject to certain optimization criteria that were incorporated in a cost function. The final design of the evaporator, which is based on 100 W of cooling power at −6.7 °C, has a length of 1.523 m and triple tube diameters of 28.5, 22.2, and 15.8 mm. The evaporator's design is such that only a single penetration through the refrigerator's wall is necessary, which greatly simplifies the construction and reduces its cost.


Articles with similar content:

COST OPTIMIZATION FOR DATA CENTER COOLING SYSTEM WITH THERMAL RESISTANCE-BASED METHOD
International Heat Transfer Conference 16, Vol.20, 2018, issue
Rong-Huan Fu, Xing Zhang
Applications
NUMERICAL SIMULATION OF THE PERFORMANCE OF A CAPILLARY THERMAL DRIVEN EJECTOR REFRIGERATOR

ICHMT DIGITAL LIBRARY ONLINE, Vol.11, 2004, issue
M. H. Shi, X. C. Wang, H. Cai
NUMERICAL BENCHMARK TEST NO. 2.1: FAUCET FLOW
Multiphase Science and Technology, Vol.3, 1987, issue 1-4
V. H. Ransom
SET-POINT ACTIVE CONTROL OF VAPOR-MODULATED LOOP HEAT PIPE
Heat Pipe Science and Technology, An International Journal, Vol.3, 2012, issue 2-4
Javier Corrochano, Donatas Mishkinis, Alejandro Torres, Francisco Romera, Tarik Kaya
EXPERIMENTAL INVESTIGATIONS ON DEVELOPMENT OF A SINGLE STAGE G-M TYPE PULSE TUBE REFRIGERATOR
Proceedings of the 24th National and 2nd International ISHMT-ASTFE Heat and Mass Transfer Conference (IHMTC-2017), Vol.0, 2017, issue
S. Anbarasu, K.N. Sai Manoj, S.K. Sarangi, Debashis Panda