Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Heat Transfer Research
Fator do impacto: 0.404 FI de cinco anos: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN On-line: 2162-6561

Volumes:
Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.v35.i56.130
8 pages

Heat Transfer in Propane Boiling on Surfaces with a Capillary-Porous Structure

Leonid L. Vasiliev, Jr.
Byelorussian Academy of Sciences; and Luikov Heat & Mass Transfer Institute, Porous Media Laboratory, P. Brovka Str. 15, 220072 Minsk, Belarus
Alexander S. Zhuravlyov
Luikov Heat & Mass Transfer Institute, National Academy of Sciences of Belarus, Porous Media Laboratory, P. Brovka Str. 15, 220072 Minsk, Belarus
A. V. Ovsyannik
P. O. Sukhoi Gomel State Technical University, Gomel; and A. V. Luikov Heat and Mass Transfer Institute, National Academy of Sciences of Belarus, Minsk, Belarus
Mikhail N. Novikov
Luikov Heat & Mass Transfer Institute, National Academy of Sciences of Belarus, Porous Media Laboratory, P. Brovka Str. 15, 220072 Minsk, Belarus
L. L. Vasiliev, Jr
Luikov Heat & Mass Transfer Institute, National Academy of Sciences of Belarus, Porous Media Laboratory, P. Brovka Str. 15, 220072 Minsk, Belarus

RESUMO

We present the results of experimental investigation of heat transfer in propane pool boiling on single horizontal stainless steel plane pipes and pipes with porous coating produced by electric arc gas-thermal spraying. We also studied the loop heat pipe evaporator wick structure made from aluminum oxide ceramic with heat generation inside the wick. Experiments were carried out at the saturation temperature Ts = +40°C (p* = p/pc = 0.081−0.323) in the range of heat loads q = 0.1−100 kW/m2 for tubes and Ts = 30°C (p* = p/pc = 0.254), q = 0.02−8 kW/m2 for the loop heat pipe evaporator.


Articles with similar content:

Heat Transfer with Propane Evaporation from a Porous Wick of Heat Pipe
Journal of Porous Media, Vol.4, 2001, issue 2
Leonid L. Vasiliev, Jr., L. L. Vasiliev, Jr, Mikhail N. Novikov, Alexander S. Zhuravlyov
Experimental Investigation of the Hydrocarbons Pool Boiling on Porous Structures
International Heat Transfer Conference 12, Vol.40, 2002, issue
Leonid L. Vasiliev, Jr., A.V. Ovsianik, Leonard L. Vasiliev, Mikhail N. Novikov, Alexander S. Zhuravlyov
HIGH SPEED FLOW VISUALIZATION OF POOL BOILING FROM STRUCTURED TUBULAR HEAT TRANSFER SURFACES
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Rudi Kulenovic, Manfred Groll, Rainer Mertz
Abstract of "HIGH SPEED FLOW VISUALIZATION OF POOL BOILING FROM STRUCTURED TUBULAR HEAT TRANSFER SURFACES"
ICHMT DIGITAL LIBRARY ONLINE, Vol.1, 2000, issue
Rudi Kulenovic, Manfred Groll, Rainer Mertz
Nucleate Pool Boiling Heat Transfer in Microgravity
Heat Transfer Research, Vol.29, 1998, issue 1-3
Koichi Inoue, Haruhiko Ohta, Suguru Yoshida, Tomoji S. Morita