Inscrição na biblioteca: Guest
Journal of Long-Term Effects of Medical Implants

Publicou 4 edições por ano

ISSN Imprimir: 1050-6934

ISSN On-line: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

A Biomechanical Comparison of Different Tendon Repair Techniques

Volume 26, Edição 2, 2016, pp. 167-171
DOI: 10.1615/JLongTermEffMedImplants.2016016536
Get accessGet access

RESUMO

Previous studies have examined multiple suture techniques for the repair of ruptured tendons. In this study, we investigated how the two- and four-stranded Krackow suture weave techniques compared with a novel Krackow/Bunnell suture technique. Our hypothesis was that the Krackow/Bunnell suture would have greater strength compared with the two- and four-stranded Krackow suture in terms of resistance to pullout from the muscle tendon. Thirty fresh bovine Achilles tendons were assigned randomly to three groups: (1) two-stranded Krackow, (2) fourstranded Krackow, and (3) the Krackow/Bunnell combination. After suture placement, all specimens were subjected to initial cyclic loading (0–200 N for 200 cycles) and then the tension to failure force defined as the pullout through the muscle tendon was evaluated. Significantly greater deformation before suture failure was seen in the Krackow/Bunnell group compared with the four-stranded Krackow construct (36.2 vs. 28.7 mm, p = 0.009), as well as greater energy required to rupture the suture (4635 vs. 3346 N/mm; p = 0.016). There was no significant difference with regard to the force to failure between the two groups (four-stranded Krackow vs. Krackow/Bunnell). The two-stranded Krackow was found to be inferior to both the four-stranded Krakow and the Krakow/Bunnell techniques with regard to load to failure. We have found that the Krackow/Bunnell suture technique is at least comparable to, if not superior to, the four-stranded Krackow technique with regard to deformation before suture failure and energy required to rupture the tendon. Therefore, the Krackow/Bunnell technique may be an optimal construct if the surgeon is concerned about suture pullout through the tendon; however, future studies evaluating this technique in the clinical setting are required before making any final conclusions for patient use.

CITADO POR
  1. Cui Juncheng , Chen Zhiwei , Wu Wente , Expression of TGF‑β1 and VEGF in patients with Achilles tendon rupture and the clinical efficacy, Experimental and Therapeutic Medicine, 2019. Crossref

  2. Fernandez John J., Distal Biceps Repair, in Wrist and Elbow Arthroscopy with Selected Open Procedures, 2022. Crossref

1042 Visualizações do artigo 25 downloads de artigos Métricas
1042 VISUALIZAÇÕES 25 TRANSFERÊNCIAS 2 Crossref CITAÇÕES Google
Scholar
CITAÇÕES

Artigos com conteúdo semelhante:

An Endomechanical Product Evaluation and Selection Program by a Healthcare Resource Management Group Purchasing Organization Journal of Long-Term Effects of Medical Implants, Vol.14, 2004, issue 4
Richard Edlich, Jean Livingston, Robin R. Szarmach
Bilateral Spontaneous Quadriceps Tendon Ruptures after Staged Bilateral Total Knee Arthroplasties: A Case Report Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 1
Preston W. Grieco, Aditya V. Maheshwari, Marine Coste, Jared M. Newman, Ahmed M. Eldib , Neil V. Shah
The Validity of Patient Satisfaction as Single Question in Outcome Measurement of Total Hip Arthroplasty Journal of Long-Term Effects of Medical Implants, Vol.18, 2008, issue 2
C. N. van Dijk, Daniel Haverkamp, Rudolf W. Poolman, R. K. Marti, M. P. van den Bekerom, Inger N. Sierevelt
An Expanded Surgical Suture and Needle Evaluation and Selection Program By a Healthcare Resource Management Group Purchasing Organization Journal of Long-Term Effects of Medical Implants, Vol.13, 2003, issue 3
Richard Edlich, Robin R. Szarmach, Jean Livingston
Effect of Zoledronic Acid on Osteoporosis after Chronic Spinal Cord Injury: A Randomized Controlled Trial Critical Reviews™ in Physical and Rehabilitation Medicine, Vol.28, 2016, issue 1-2
Raji Thomas, Bobeena Chandy, George Tharion, Shiela Mary Varghese

Próximos artigos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa Políticas de preços e assinaturas Begell House Contato Language English 中文 Русский Português German French Spain