Comparison of Inflammatory Cell-Induced Corrosion and Electrocautery-Induced Damage of Total Knee Implants

Volume 29, Edição 3, 2019, pp. 231-238
DOI: 10.1615/JLongTermEffMedImplants.2020033871
Get accessGet access

RESUMO

Recently, inflammatory cell-induced corrosion (ICIC), a unique type of damage, has been reported in cobalt-chromium (CoCr) implants, but the mechanism remains poorly understood and controversial because electrocautery damage has also been shown to produce similar findings. This study aimed to distinguish between these two damage mechanisms. Forty-one CoCr primary total knee arthroplasty specimens were collected at time of necropsy. After removal and cleaning, light microscopy was used to identify areas of ICIC-like damage scars. A CoCr knee implant was intentionally damaged by electrocautery from both Bovie and Aquamantys sources using a 3-second hover method with 3 different energy settings for comparison to necropsy findings. Average roughness (Ra), max peak-to-valley height (Rmax), kurtosis (Rk), and skewness (Rsk) measurements were collected to represent the topography on the damaged areas for the CoCr implants. Necropsy implants showed signs of ICIC in 7 of 41 implants (17%) examined. Fe/C ratios of the Bovie electrocautery-damaged knee implant were shown to be statistically higher than those of necropsy-retrieved implants. Median Ra measurements were statistically less (P = 0.008) for Bovie-damaged areas compared to ICIC-dam-aged areas on CoCr. Median Rmax and Ra measurements were statistically less (P = 0.012, P < 0.001, respectively) for Aquamantys-damaged areas compared to ICIC-damaged areas on CoCr. While the visual patterns seen in necropsy-retrieved implants appeared similar to those with the intentionally damaged CoCrMo implant, the contents of the corroded regions are unique. The difference in roughness found on ICIC-damaged and electrocautery-damaged regions also indicates examination of surface topography as another distinguishing feature between the two mechanisms.

Referências
  1. Gibon E, Goodman MJ, Goodman SB. Patient satisfaction after total knee arthroplasty: a realistic or imaginary goal? Orthop Clin North Am. 2017;48(4):421-31. .

  2. Wylde V, Hewlett S, Learmonth ID, Dieppe P. Persistent pain after joint replacement: prevalence, sensory qualities, and postoperative determinants. Pain. 2011;152(3):566-72. .

  3. Beswick AD, Wylde V, Gooberman-Hill R, Blom A, Dieppe P. What proportion of patients report long-term pain after total hip or knee replacement for osteoarthritis? A systematic review of prospective studies in unselected patients. BMJ Open. 2012;2(1):e000435. .

  4. Sharkey PF, Lichstein PM, Shen C, Tokarski AT, Parvizi J. Why are total knee arthroplasties failing today-has anything changed after 10 years? J Arthroplasty. 2014 Sep 1;29(9):1774-8. .

  5. Gilbert JL, Sivan S, Liu Y, Kocagoz SB, Arnholt CM, Kurtz SM. Direct in vivo inflammatory cell-induced corrosion of CoCrMo alloy orthopedic implant surfaces. J Biomed Mater Res Part A. 2015 Jan;103(1):211-23. .

  6. Cerquiglini A, Henckel J, Hothi HS, Di Laura A, Skinner JA, Hart AJ. Inflammatory cell-induced corrosion in total knee arthroplasty: a retrieval study. J Biomed Mater Res Part B: Appl Biomater. 2018 Jan;106(1):460-7. .

  7. Gallagher K, Dhinsa B, Miles J. Electrosurgery. Surgery (Oxford). 2011 Feb 1;29(2):70-2. .

  8. Gordon PH, Nivatvongs S. Principles and practice of surgery for the colon, rectum and anus (2nd edition), New York: Quality Medical Publishings Inc.; 1999. p. 174-179. .

  9. Yuan N, Park SH, Luck Jr JV, Campbell PA. Revisiting the concept of inflammatory cell-induced corrosion. J Biomed Mater Res Part B: Appl Biomater. 2018 Apr;106(3):1148-55. .

  10. Kubacki GW, Sivan S, Gilbert JL. Electrosurgery induced damage to Ti-6Al-4V and CoCrMo alloy surfaces in orthopedic implants in vivo and in vitro. J Arthroplasty. 2017 Nov 1;32(11):3533-8. .

  11. ASTM F561-13. Standard practice for retrieval and analysis of medical devices, and associated tissues and fluids. West Conshohocken, PA: ASTM International; 2013. .

  12. Jacobs JJ, Gilbert JL, Urban RM. Current concepts review-corrosion of metal orthopaedic implants. J Bone Joint Surg. 1998 Feb 1;80(2):268-82. .

  13. Jacobs JJ, Hallab NJ. Loosening and osteolysis associated with metal-on-metal bearings: a local effect of metal hypersensitivity? J Bone Joint Surg. 2006;88:1171-1172. .

  14. Jacobs JJ, Hallab NJ, Urban RM, Wimmer MA. Wear particles. J Bone Joint Surg. 2006 Apr 1;88(Suppl 2):99-102. .

  15. Di Laura A, Hothi HS, Meswania JM, Whittaker RK, de Villiers D, Zustin J, Blunn GW, Skinner JA, Hart AJ. Clinical relevance of corrosion patterns attributed to inflammatory cell-induced corrosion: a retrieval study. J Biomed Mater Res Part B: Appl Biomater. 2017 Jan;105(1):155-64. .

  16. Arnholt CM, MacDonald DW, Malkani AL, Klein GR, Rimnac CM, Kurtz SM, Kocagoz SB, Gilbert JL. Corrosion damage and wear mechanisms in long-term retrieved CoCr femoral components for total knee arthroplasty. J Arthroplasty. 2016 Dec 1;31(12):2900-6. .

  17. Campbell P, Yuan N, Luck J, Courpron P, Park SH. Re-examining the concept of inflammatory cell-induced corrosion. Bone Joint J. 2017;99(Suppl 3):57. .

  18. Heyse TJ, Elpers ME, Nawabi DH, Wright TM, Haas SB. Oxidized zirconium versus cobalt-chromium in TKA: profilometry of retrieved femoral components. Clin Orthop. 2014 Jan 1;472(1):277-83. .

  19. Chapman-Sheath P, Cain S, Bruce WJ, Chung WK, Walsh WR. Surface roughness of the proximal and distal bearing surface of mobile bearing total knee prostheses. J Arthroplasty. 2002 Sep 1;17(6):713-7. .

  20. Arnholt CM, MacDonald DW, Klein GR, Cates HE, Rimnac CM, Kurtz SM, Kocagoz S, Chen AF. What is the incidence of cobalt-chromium damage modes on the bearing surface of contemporary femoral component designs for total knee arthroplasty? J Arthroplasty. 2018 Oct 1;33(10):3313-9. .

  21. Que L, Topoleski LT, Parks NL. Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints. J Biomed Mater Res. 2000;53(1):111-8. .

CITADO POR
  1. Prestat M., Thierry D., Corrosion of titanium under simulated inflammation conditions: clinical context and in vitro investigations, Acta Biomaterialia, 136, 2021. Crossref

  2. Miller Kirsten C., Holloway Matthew B., Morrow Brian R., Smith Richard A., Mihalko William M., In-Vitro Cell-Induced Corrosion by Macrophages on Cobalt-Chromium-Molybdenum Alloy, The Journal of Arthroplasty, 37, 6, 2022. Crossref

3206 Visualizações do artigo 26 downloads de artigos Métricas
3206 VISUALIZAÇÕES 26 TRANSFERÊNCIAS 2 Crossref CITAÇÕES Google
Scholar
CITAÇÕES

Artigos com conteúdo semelhante:

Radiographic Evaluation of Vertical and Horizontal Fit in Single Implant Crowns Fabricated by CAD/CAM Systems: A Retrospective Study Journal of Long-Term Effects of Medical Implants, Vol.31, 2021, issue 4
Keerthi Shashanka, Harini K. Sri, Nabeel Ahmed
Evaluating Vitality and Periodontal Sensitivity of Teeth Adjacent to the Site of Open Sinus Lift Surgery before and after Treatment: A Case Series Study Journal of Long-Term Effects of Medical Implants, Vol.30, 2020, issue 2
Negar Azami, Amir Moeintaghavi, Mohammad Sadegh Zohrevand, Majid Reza Mokhtari, Hamid Jafarzadeh, Farid Shiezadeh
Efficacy of Application of Platelet-Rich Fibrin for Improvement of Implant Stability: A Clinical Trial Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 4
Masoumeh Khoshhal, Ehsan Houshyar, Leili Tapak, Ali Ghamari, Parviz Torkzaban
A New Classification of Anterior Mandible Edentulous Ridge Based on Cone Beam Computed Tomography Journal of Long-Term Effects of Medical Implants, Vol.31, 2021, issue 1
Yaser Safi, Zahra Vasegh, Reza Amid, Mitra Ghazizadeh Ahsaie
Measurements of Surface and Subsurface Damage in Retrieved Polyethylene Tibial Inserts of a Contemporary Design Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 1
Jan-M. Brandt, David W. Holdsworth, Matthew G Teeter, Eric R. Bohm, Douglas D. R. Naudie, Richard W. McCalden

Próximos artigos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa Políticas de preços e assinaturas Begell House Contato Language English 中文 Русский Português German French Spain