Inscrição na biblioteca: Guest
Portal Digital Begell Biblioteca digital da Begell eBooks Diários Referências e Anais Coleções de pesquisa
Journal of Long-Term Effects of Medical Implants
SJR: 0.145 SNIP: 0.491 CiteScore™: 0.89

ISSN Imprimir: 1050-6934
ISSN On-line: 1940-4379

Journal of Long-Term Effects of Medical Implants

DOI: 10.1615/JLongTermEffMedImplants.v14.i2.20
14 pages

Comparison of Total Body Tissue Interface Pressure of Specialized Pressure-Relieving Mattresses

William L. Hickerson
Clinical Professr of Surgery. Medical & Surgical Associates of Georgia, PC, Augusta, Georgia, USA
George M. Slugocki
Medical & Surgical Associates of Georgia, PC, Augusta, Georgia, USA
Reuben L. Thaker
Medical & Surgical Associates of Georgia, PC, Augusta, Georgia, USA
Robert Duncan
University of Miami School of Medicine Florida Cancer Data System, Coral Gables, Florida, USA
John F. Bishop
Medical & Surgical Associates of Georgia, PC, Augusta, Georgia, USA
Judy K. Parks
Medical & Surgical Associates of Georgia, PC, Augusta, Georgia, USA

RESUMO

Objective. The pressure-relieving ability of three specialized support surface mattresses was investigated and compared to a standard hospital mattress by measuring total body tissue interface pressure in a laboratory experiment designed to simulate clinical conditions predisposing to formation of pressure ulcers. Summary Background Data. Pressure ulcers are commonly seen in the elderly; in patients with trauma, burns, spinal cord injury, neurological deficits, peripheral vascular disease, and stroke; and in other patient groups with debilitating or emaciating illness. They represent from 4 to 29% of all hospital admissions. This study was undertaken to compare three different types of specialty beds to a standard hospital mattress in order to find a mattress that prevents the occurrence of pressure ulcers. Methods. The tested beds and mattresses were the Orthoderm™ Convertible II (Bio-Clinic Inc., Ontario, Canada) low air-loss mattress on a Stryker® PMS (Stryker Inc., Kalamazoo, Michigan, USA) bed; the FluidAir Elite® (KCI Inc., San Antonio, Texas, USA) air-fluidized bed; the Pegasus Airwave™ mattress (Pegasus Airwave Inc., Boca Raton, Florida, USA) on a Stryker PMS bed; and a standard hospital mattress on a Stryker PMS bed. The nineteen test subjects were all healthy with exclusion criteria of spinal cord injury, immobility, or other neurological or physical impairment. The Force Management System™ (Numotech Inc., Northridge, California, USA) was used to measure tissue interface pressure. Results: The study data show that the Pegasus Airwave mattress total surface pressure values of the anatomical regions (total body, torso, hips) of the body are lower than those of the other three tested mattresses. The total body and hip pressure resulting from pressure maturation is significantly less on the Pegasus Airwave mattress than on to the hospital bed, the air-fluidized bed, and the low air-loss bed. Conclusions: The Pegasus Airwave mattress outperforms the other tested support surfaces by decreasing overall pressure. Therefore, the Pegasus Airwave mattress is an excellent addition to augment nursing care in the prevention and treatment of pressure sores.


Articles with similar content:

Pressure Ulcer Prevention
Journal of Long-Term Effects of Medical Implants, Vol.14, 2004, issue 4
William B. Long III, Richard Edlich, Ralph M. Buschbacher, Eva K. Ma, Jocelynn H. Gebhart, Kathryne L. Winters, Charles R. Woodard
Distraction over Nail Using Circular External Fixation for Septic Pseudarthrosis of the Tibia
Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 2
Vasileios Polyzois, Spyridon G. Pneumaticos, Pavlos Romoudis, Andreas F. Mavrogenis, Orestis Karargyris, Christos Zafeiris, Lampros Giuseppe Morassi
Scientific Basis for the Selection of Absorbent Underpads that Remain Securely Attached to Underlying Bed or Chair
Journal of Long-Term Effects of Medical Implants, Vol.16, 2006, issue 1
William B. Long III, Richard Edlich, Kathryne L. Winters
Clinical Evaluation of a New Total Hip Prosthetic Design: 100 Consecutive Cementless Total Hip Arthroplasties Using Sulzermedica's "Natural Hip" With Two- to Six-Year Clinical and Radiographic Follow-Up
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 1&2
Thomas B. Pace
Reconstruction Plate-Based Antibiotic Cement Spacers: Clinical Outcomes and Description of Technique
Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 1
Robert Pivec, Aditya V. Maheshwari, Qais Naziri, Roby Abraham