ライブラリ登録: Guest
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集
Critical Reviews™ in Biomedical Engineering
SJR: 0.26 SNIP: 0.375 CiteScore™: 1.4

ISSN 印刷: 0278-940X
ISSN オンライン: 1943-619X

Critical Reviews™ in Biomedical Engineering

DOI: 10.1615/CritRevBiomedEng.2019026533
pages 179-191

Development of Electrochemical Methods to Enzymatically Detect Lactate and Glucose Using Imaginary Impedance for Enhanced Management of Glycemic Compromised Patients

Blake Morrow
School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ
Aldin Malkoc
School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ; St. George's University School of Medicine, True Blue, Grenada
Tiffany Gong
School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ
David Probst
School of Biological and Health Systems Engineering, Arizona State University, Tempe, Arizona
Chi Lin
School of Biological and Health Systems Engineering, Arizona State University, Tempe, AZ
Ayan Sen
Mayo Clinic, Critical Care, Phoenix, AZ
Jeffrey T. La Belle
School of Biological and Health Systems Engineering, Arizona State University, Tempe, Arizona

要約

Lactate is an important biological marker that can provide valuable information for patients who have experienced a traumatic injury. Additionally, when coupled with glucose, the severity and likely prognosis of a traumatic injury can be determined. Because monitoring various markers proves useful in diagnosis and treatment of trauma patients, monitoring both glucose and lactate simultaneously may be especially useful for diabetic patients who have suffered a traumatic injury. Previously, using electrochemical impedance spectroscopy (EIS), a sensor capable of measuring two affinity-based biomarkers simultaneously was demonstrated using the biomarker's specific optimal frequency to develop a deconvolution algorithm, which allowed for the measurement of two biomarkers from a single signal. Herein, while developing an EIS lactate sensor, dual enzymatic biomarker detection of lactate and glucose via EIS was also attempted. Both biomarkers were validated individually with the lactate sensor being additionally validated on whole blood samples. The EIS lactate biosensor achieved a range of detection from 0 to 32 mM of lactate and the glucose sensor a range of 0–100 mg/dL of glucose, which are representative of the likely physiological ranges that trauma patients experience. However, the preliminary attempt of dual marker detection was unsuccessful due to suspected accumulation of reduced redox probe on the surface of the self-assembled monolayer (SAM). Individually, the optimal frequency of lactate was determined to be 69.75 Hz and that of glucose was determined to be 31.5 Hz. However, when combined onto one sensor, no discernable optimal frequency could be determined which again was suspected to be due to the accumulation of the reduced redox probe at the surface of the SAM.

参考

  1. Brooks GA. , The lactate shuttle during exercise and recovery. Med Sci Sports Exerc. 1986;18(3):360–8.

  2. American Diabetes Association. Diagnosis and classification of diabetes mellitus. Diabetes Care. 2006;29(1): S43–S48.

  3. Faul M, Xu L, Wald MM, Coronado V. , Traumatic brain injury in the United States. Natl Cent Inj Prev Control Cent Dis Control Prev. Atlanta; 2010.

  4. Gaieski DF, Drumheller BC, Goyal M, Fuchs BD, Shofer FS, Zogby K. , Accuracy of handheld point-of-care fingertip lactate measurement in the emergency department. West J Emerg Med. 2013;14(1):58–62.

  5. Dellinger RP, Levy MM, Carlet JM, Bion J, Parker MM, Jaeschke R, Reinhart K, Angus DC, Brun-Buisson C, Beale R., Surviving Sepsis Campaign: international guidelines for management of severe sepsis and septic shock: 2008. Intensive Care Med. 2008;34(1):17–60.

  6. Faude O, Kindermann W, Meyer T. , Lactate threshold concepts: how valid are they? Sports Med Auckl NZ. 2009; 39(6):469–90.

  7. Association AD. , Physical activity/exercise and diabetes. Diabetes Care. 2004 Jan 1;27(suppl 1):s58–s62.

  8. Boer RA, Lok DJ, Jaarsma T, van der Meer P, Voors AA, Hillege HL, van Veldhuisen DJ., Predictive value of plasma galectin-3 levels in heart failure with reduced and preserved ejection fraction. Ann Med. 2011;43(1):60–8.

  9. Sullivan SD, Garrison Jr LP, Rinde H, Kolberg J, Moler EJ. , Cost-effectiveness of risk stratification for preventing type 2 diabetes using a multi-marker diabetes risk score. J Med Econ. 2011;14(5):609–16.

  10. Wang TJ, Gona P, Larson MG, Levy D, Benjamin EJ, Tofler GH, Jacques PF, Meigs JB, Rifai N, Selhub J. , Multiple biomarkers and the risk of incident hypertension. Hypertension. 2007;49(3):432–8.

  11. Wang TJ, Gona P, Larson MG, Tofler GH, Levy D, Newton-Cheh C, Jacques PF, Rifai N, Selhub J, Robins SJ. , Multiple biomarkers for the prediction of first major cardiovascular events and death. N Engl J Med. 2006;355(25):2631–9.

  12. Glenn TC, Kelly DF, Boscardin WJ, McArthur DL, Vespa P, Oertel M, Hovda DA, Bergsneider M, Hillered L, Martin NA., Energy dysfunction as a predictor of outcome after moderate or severe head injury: indices of oxygen, glucose, and lactate metabolism. J Cereb Blood Flow Metab. 2003 Oct 1;23(10):1239–50.

  13. Sammour T, Kahokehr A, Caldwell S, Hill AG., Venous glucose and arterial lactate as biochemical predictors of mortality in clinically severely injured trauma patients— a comparison with ISS and TRISS. Injury. 2009 Jan 1;40(1):104–8.

  14. Laird AM, Miller PR, Kilgo PD, Meredith JW, Chang MC. , Relationship of early hyperglycemia to mortality in trauma patients. J Trauma Acute Care Surg. 2004 May;56(5):1058–62.

  15. Clarke SF, Foster JR. , A history of blood glucose meters and their role in self-monitoring of diabetes mellitus. Br J Biomed Sci Lond. 2012;69(2):83–93.

  16. Huckabee WE. , Relationships of pyruvate and lactate during anaerobic metabolism. I. Effects of infusion of pyruvate or glucose and of hyperventilation. J Clin Invest. 1958 Feb;37(2):244–54.

  17. Adamson TL, Eusebio FA, Cook CB, LaBelle JT. , The promise of electrochemical impedance spectroscopy as novel technology for the management of patients with diabetes mellitus. Analyst. 2012;137(18):4179–87.

  18. Chang B-Y, Park S-M. , Electrochemical impedance spectroscopy. Annu Rev Anal Chem. 2010;3(1):207–29.

  19. Lasia A. , Electrochemical impedance spectroscopy and its applications. Mod Asp Electrochem [Internet]. Boston: Springer; 2002 [cited 2018 Apr 16]. p. 143–248. Available from: https:// link.springer.com/chapter/10.1007/0-306-46916-2_2.

  20. Lisdat F, Schäfer D. , The use of electrochemical impedance spectroscopy for biosensing. Anal Bioanal Chem. 2008 Jul;391(5):1555–67.

  21. Lin C, Ryder L, Probst D, Caplan M, Spano M, LaBelle J. , Feasibility in the development of a multi-marker detection platform. Biosens Bioelectron. 2017;89:743–9.

  22. Adamson TL, Cook CB, LaBelle JT. , Detection of 1, 5-anhydroglucitol by electrochemical impedance spectroscopy. J Diabetes Sci Technol. 2014;8(2):350–5.

  23. Malkoc A, Probst D, Lin C, Khanwalker M, Beck C, Cook C, La Belle JT. , Enhancing glycemic control via detection of insulin using electrochemical impedance spectroscopy. J Diabetes Sci Technol. 2017 Sep;11(5): 930–5.

  24. Lin C, Ryder L, Probst D, Caplan M, Spano M, LaBelle J. , Feasibility in the development of a multi-marker detection platform. Biosens Bioelectron. 2017 Mar 15;89(Pt 2):743–9.

  25. Medbø JI, Mamen A, Olsen OH, Evertsen E. , Examination of four different instruments for measuring blood lactate concentration. Scand J Clin Lab Invest. 2000 Jan 1;60(5):367–80.


Articles with similar content:

Electrochemical Detection of Fertility Hormones
Critical Reviews™ in Biomedical Engineering, Vol.47, 2019, issue 3
Victoria Smith, Jared Johns, Sandhya Santhanaraman, Mackenzie M. Honikel, Stephanie Maxwell, Jeffrey T. La Belle, Mukund Khanwalker
Toward a Label-Free Electrochemical Impedance Immunosensor Design for Quantifying Cortisol in Tears
Critical Reviews™ in Biomedical Engineering, Vol.47, 2019, issue 3
Brittney A. Cardinell, Mark L. Spano, Jeffrey T. La Belle
An Experimental Platform for Characterizing Cancer Biomarkers with Capabilities in Noninvasive and Continuous Screening
Critical Reviews™ in Biomedical Engineering, Vol.47, 2019, issue 3
Mackenzie M. Honikel, Jeffrey T. La Belle
Comparison of Median and Radial Sensory Studies to the Thumb
Journal of Long-Term Effects of Medical Implants, Vol.16, 2006, issue 5
Ralph M. Buschbacher, Andrew Berkson, James Lohman
Median and Ulnar Antidromic Sensory Studies to the Fourth Digit
Journal of Long-Term Effects of Medical Implants, Vol.16, 2006, issue 5
Ralph M. Buschbacher, Andrew Berkson, James Lohman