PERFORMANCE ENHANCEMENT OF TWO PHASE THERMOSYPHON SOLAR WATER HEATER USING SURFACTANT
巻 5,
発行 1-4, 2014,
pp. 663-671
DOI: 10.1615/HeatPipeScieTech.v5.i1-4.770
要約
In this study the thermal performance of two different wickless heat pipe solar collectors were investigated by using pure water and water-surfactant for different coolant mass flow rates and tilt angles (20°, 31.5°, 40°, 50° and 60°). First collector uses only pure water; the second one utilizes water with 150 ppm 2-ethyl-hexanol as coolant for the investigation. Experiments were carried out for the two collectors under same experimental conditions. It is observed that the performance of the solar collector that uses 2-ethyl-hexanol surfactant with water as coolant is better compared to solar collectors that utilize pure water.
512 記事の閲覧数
2 記事のダウンロード
記事の統計
類似内容の記事:
最新号
PREFACE: SELECTED PAPERS FROM THE JOINT 18TH INTERNATIONAL HEAT PIPE CONFERENCE AND THE 12TH INTERNATIONAL HEAT PIPE SYMPOSIUM
FLUID FLOW AND HEAT TRANSFER CHARACTERISTICS OF A JEST-TYPE LOOP THERMOSYPHON
EFFECT OF CONDENSER TEMPERATURE ON THE START-UP OF A PULSATING HEAT PIPE
DESIGN, MANUFACTURING, AND CHARACTERIZATION OF COPPER CAPILLARY STRUCTURES FOR LOOP HEAT PIPES
INNOVATIVE THERMAL DESIGN SATELLITE WITH NETWORKED VARIABLE-CONDUCTANCE OSCILLATING HEAT PIPES
THERMAL MANAGEMENT USING COPPER-METHANOL HEAT PIPES FOR RADIO TRANSMITTER SYSTEMS
EXPERIMENTAL STUDY OF THE PERFORMANCE OF WATER–COPPER SCREEN MESH WICK HEAT PIPES OPERATING IN POWER CYCLES