ライブラリ登録: Guest
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集
Heat Transfer Research
インパクトファクター: 0.404 5年インパクトファクター: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN 印刷: 1064-2285
ISSN オンライン: 2162-6561

巻:
巻 50, 2019 巻 49, 2018 巻 48, 2017 巻 47, 2016 巻 46, 2015 巻 45, 2014 巻 44, 2013 巻 43, 2012 巻 42, 2011 巻 41, 2010 巻 40, 2009 巻 39, 2008 巻 38, 2007 巻 37, 2006 巻 36, 2005 巻 35, 2004 巻 34, 2003 巻 33, 2002 巻 32, 2001 巻 31, 2000 巻 30, 1999 巻 29, 1998 巻 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2018020698
pages 183-194

EFFECTS OF SCALING ON PRESSURE DROP AND TUBE WALL TEMPERATURE OF STEAM INJECTION BOILERS REUSING OIL FIELD PRODUCED WATER

Wei Zhang
College of Pipeline and Civil Engineering, China University of Petroleum (East China), Qingdao, Shandong, P.R. China, 266580
Bin Li
College of Pipeline and Civil Engineering, China University of Petroleum (East China), Qingdao, Shandong, P.R. China, 266580
Liang Gong
Department of Energy and Power Engineering, China University of Petroleum (East China), 66 West Changjiang Rd. Huangdao District, Qingdao 266580, PR. China

要約

Reusing produced water in steam boilers can save fresh water. However, because of the strong scaling characteristics of produced water, the operation condition of a steam injection boiler varies after reusing the produced water. A computing program is developed to theoretically study the effects of scaling on the pressure drop and the tube wall temperature of a steam injection boiler, and to finally find a key parameter used to monitor the operation safety of a steam injection boiler. The calculation results show that the thermal conductivity of water scale has almost no effect on the pressure drop and that the flow rate has a small effect on the wall temperature. The pressure drop is increased with increase of the scale thickness and flow rate and with decrease of the feed water pressure. While the wall temperature increases when the water scale thickness and feed water pressure increase, the thermal conductivity of water scale decreases. The maximal allowable pressure drop as a key parameter used to guide the boiler cleaning is obtained in this paper. It is not constant but depends on the thermal conductivity of water scale, the feed water pressure, and the flow rate. Once the pressure drop reaches the allowable value, the water scale must be removed by chemical cleaning to ensure the safe operation of a steam injection boiler.


Articles with similar content:

A Study on Post-CHF Heat Transfer at Near-Critical Pressure
International Heat Transfer Conference 15, Vol.16, 2014, issue
Takashi Mawatari, Keishi Kariya, Hideo Mori
THE ON-LINE CALCULATION OF CONDENSER PERFORMANCE AND OPTIMAL CLEANING INTERVAL
International Heat Transfer Conference 10, Vol.26, 1994, issue
Richard E. Putman
TRANSIENT HEAT BEHAVIOURS IN WELL AND SURROUNDING FORMATION
Second Thermal and Fluids Engineering Conference, Vol.38, 2017, issue
Xingru Wu, Fayong Yuan, Yin Zhang, Yu Jiang
AN EXPERIMENTAL AND ANALYTICAL STUDY ON CHF PHENOMENON APPEARING IN A BOTTOM-CLOSED VERTICAL TUBE FOR VAPOR/LIQUID DENSITY RATIO IN THE RANGE OF 0.000624-0.136
International Heat Transfer Conference 10, Vol.20, 1994, issue
Yoshiro Katto, K. Sugiyama , M. Fujita
Experimental Investigation on a Full Scale Thermo-syphon Reboiler
ICHMT DIGITAL LIBRARY ONLINE, Vol.19, 1981, issue
Peter von Bockh