ライブラリ登録: Guest
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集
Heat Transfer Research
インパクトファクター: 0.404 5年インパクトファクター: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN 印刷: 1064-2285
ISSN オンライン: 2162-6561

巻:
巻 51, 2020 巻 50, 2019 巻 49, 2018 巻 48, 2017 巻 47, 2016 巻 46, 2015 巻 45, 2014 巻 44, 2013 巻 43, 2012 巻 42, 2011 巻 41, 2010 巻 40, 2009 巻 39, 2008 巻 38, 2007 巻 37, 2006 巻 36, 2005 巻 35, 2004 巻 34, 2003 巻 33, 2002 巻 32, 2001 巻 31, 2000 巻 30, 1999 巻 29, 1998 巻 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2014006552
pages 767-793

EFFECT OF INTERNAL HEAT GENERATION ON THE APPLICABILITY OF DIFFERENT LUMPED MODELS WITH UNSTEADY ONE-DIMENSIONAL CONDUCTION

Behrooz Abbasi Souraki
Chemical Engineering Department, Faculty of Engineering, University of Guilan, Rasht, Iran
N. Assareh
Chemical Engineering Department, Faculty of Engineering, University of Guilan, Rasht, Iran
M. Omidi
Chemical Engineering Department, Faculty of Engineering, University of Guilan, Rasht, Iran

要約

In this study, the effect of internal heat generation as well as the Biot number on the accuracy and applicability of lumped models in unsteady one-dimensional heat transfer problems is investigated. The simple classical lumped capacity approach and also improved lumped models based on the Hermite and polynomial approximation approaches were used to obtain the average temperature and heat flux in the spatial direction. The applicability of the lumped models was quantified using the dimensionless number B = hR/k and dimensionless heat source G = R2q°/(T0 − T) that depend on the objects geometry, thermal and physical properties, the value of internal heat generation, and on the environmental conditions they are subjected to. The range of application of different lumped models was analyzed by evaluation of the average relative error between the solution of approximate lumped models and a reference exact solution of the original partial differential equation for a whole time domain at B and −G numbers equal between 0 and 20. The results show that at the B numbers lower than 13, the variations of the relative error with the internal heat generation passes through a minimum at a dimensionless internal heat generation lower than 5, and, thus, in these ranges of B and G, the internal heat generation has increasing effect on the precision of the lumped models.


Articles with similar content:

Accuracy and Sensitivity of Surface Resistance Measurements of High-Temperature Superconductor Films Using Quasioptical Dielectric Resonators
Telecommunications and Radio Engineering, Vol.60, 2003, issue 5&6
A. A. Barannik, S. A. Bunyaev, Nikolay T. Cherpak
MATHEMATICAL ANALYSIS OF LAMINAR COUNTERFLOW PARALLEL PLATE HEAT EXCHANGERS FOR LARGE PRANDTL AND PECLET NUMBERS
ICHMT DIGITAL LIBRARY ONLINE, Vol.13, 2008, issue
Marcos Vera, Amable Linan
MIXED CONVECTION BOUNDARY-LAYER FLOW OVER A SEMI-INFINITE VERTICAL SURFACE IMPLANTED IN A PERMEABLE MEDIUM
Special Topics & Reviews in Porous Media: An International Journal, Vol.8, 2017, issue 1
B. B. Singh, C. N. Guled
Numerical Investigation of Impinging Two-Dimensional Jet on an Inclined Flat Plate
International Journal of Fluid Mechanics Research, Vol.36, 2009, issue 5
A. Abdel-Fattah, Mostafa A. Abd El-Baky
Magnetohydrodynamic Free Convection of a Large Prandtl Number Liquid Over a Nonisothermal Two-Dimensional Body
International Journal of Fluid Mechanics Research, Vol.33, 2006, issue 2
Mohamed F. El-Amin, M. A. EL-Hakiem, Rama Subba Reddy Gorla