ライブラリ登録: Guest
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集
Heat Transfer Research
インパクトファクター: 0.404 5年インパクトファクター: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN 印刷: 1064-2285
ISSN オンライン: 2162-6561

巻:
巻 50, 2019 巻 49, 2018 巻 48, 2017 巻 47, 2016 巻 46, 2015 巻 45, 2014 巻 44, 2013 巻 43, 2012 巻 42, 2011 巻 41, 2010 巻 40, 2009 巻 39, 2008 巻 38, 2007 巻 37, 2006 巻 36, 2005 巻 35, 2004 巻 34, 2003 巻 33, 2002 巻 32, 2001 巻 31, 2000 巻 30, 1999 巻 29, 1998 巻 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2017013252
pages 31-44

NUMERICAL INVESTIGATION OF NONUNIFORM SPRAY EFFECT ON THE COOLING PERFORMANCE OF A LARGE-SCALE COOLING TOWER

Yuanbin Zhao
School of Energy and Power Engineering, Shandong University, Jinan 250061, China
Xuehong Chen
School of Energy and Power Engineering, Shandong University, Jinan 250061, China
Guoqing Long
Guangdong Electricity Power Design Institute, Guangzhou 510660, China
Fengzhong Sun
School of Energy and Power Engineering, Shandong University, Jinan 250061, China

要約

To study the effect of water spray layout on the cooling performance of a natural draft wet cooling tower (NDWCT), a three-dimensional (3D) numerical model was developed and validated. The design working conditions for one large-scale NDWCT were adopted to analyze the effect of nonuniform spray, by which the water mass flow rate in the tower outer zone was greater than that in the tower inner zone. By numerical simulation, the distributions of the air velocity and water temperature inside NDWCT could be computed and analyzed in detail. Comparing the distributions of the air velocity and water temperature between the uniform spray and nonuniform spray, it could be found that the effect of the nonuniform spray rested with the special working conditions. When the rate of air mass flow through the tower is high, the air flow field dominates the heat and mass transfer, and then the effect of the nonuniform spray is insignificant. When the rate of air mass flow through tower is low, the effect of the nonuniform spray is positive and obvious. Compared with the uniform spray, the nonuniform spray cools the water in the tower inner zone sufficiently, and then improves the cooling performance of NDWCT. Besides, the effect of the nonuniform spray on the tower is also impacted by ambient crosswinds.


Articles with similar content:

NUMERICAL STUDY OF THERMAL PERFORMANCE FOR LARGE-SCALE WET COOLING TOWER EQUIPPED WITH A FAN DRIVEN BY WATER DROPPING POTENTIAL ENERGY
International Heat Transfer Conference 16, Vol.9, 2018, issue
Chaoqun Ma, Zhigang Dang, Ming Gao, Yuetao Shi, Yang Zhou
EFFECTS OF ANNULAR JET IN INSIDE VAPOR DEPOSITION WITH APPLICATIONS TO OPTICAL FIBER MANUFACTURE
International Heat Transfer Conference 10, Vol.19, 1994, issue
M. Choi, K.S. Park
NUMERICAL STUDY AND EXPERIMENTAL VALIDATION OF THE WATER FILMS AND THE DETACHMENT OF DROPS ON DRIFT ELIMINATORS
Computational Thermal Sciences: An International Journal, Vol.7, 2015, issue 2
J. Ruiz, Antonio Viedma, M. Lucas, B. Zamora , Antonio S. Kaiser, Javier Lopez
ATOMIZERS FOR MOLTEN METALS: MACROSCOPIC PHENOMENA AND ENGINEERING ASPECTS
Atomization and Sprays, Vol.9, 1999, issue 6
L. A. Nunez, R. Palma, T. Lobel
NUMERICAL ANALYSIS OF Si POWDER EVAPORATION IN AXISYMMETRIC REACTOR WITH COAXIAL CONVERGENT NITROGEN PLASMA FLOW
Progress in Plasma Processing of Materials, 1999, Vol.1, 1999, issue
Zivota G. Kostic, Pavle B. Pavlovic, Dejan B. Cvetinovic, Predrag Lj. Stefanovic