ライブラリ登録: Guest
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集
Journal of Long-Term Effects of Medical Implants
SJR: 0.145 SNIP: 0.491 CiteScore™: 0.89

ISSN 印刷: 1050-6934
ISSN オンライン: 1940-4379

Journal of Long-Term Effects of Medical Implants

DOI: 10.1615/JLongTermEffMedImplants.2013007133
pages 293-303

Assessment of Static Progressive Stretch for the Treatment of Shoulder Stiffness: A Prospective Case Series

Aaron J. Johnson
Rubin Institute for Advanced Orthopedics, Center for Joint Preservation and Reconstruction, Sinai Hospital of Baltimore, Baltimore, Maryland
Shelton A. McKenzie
Howard University Department of Orthopaedic Surgery, 2041 Georgia Avenue, N.W., Washington, District of Columbia 20060
Slif D. Ulrich
Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, Maryland 21215
Thorsten M. Seyler
Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, 2401 West Belvedere Avenue, Baltimore, Maryland 21215
Kimona Issa
School of Health and Medical Sciences, Department of Orthopaedics, Seton Hall University, 400 S Orange Ave, South Orange, New Jersey
Robert Pivec
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center/University Hospital Brooklyn, Brooklyn, NY
Michael A. Mont
Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, Maryland

要約

Introduction: The purpose of this study was to evaluate the use of a patient-directed static progressive stretch orthosis for the treatment of shoulder stiffness. Methods: Twenty-three patients who had limitations in range of motion of the shoulder and who had failed conventional physical therapy methods were studied. This cohort included 15 women and 8 men with a mean age of 53 years. Treatment comprised one to three 30- to 60-minute sessions per day with a patient-controlled orthosis utilizing static progressive stretch. The patients adjusted the degree of stretch at 5-minute intervals as tolerated. Compliance, range of motion, patient satisfaction, and complications were assessed, and a two-way repeated measure ANOVA was performed to assess the effects of age or gender. Results: After a mean treatment duration of 10 weeks (range, 4 to 19 weeks), the patients gained a mean of 22° (range, −47 to 57°) of external rotation, 18° (range, −19 to 55°) of internal rotation, 46° (range, 3 to 97°) of abduction, and 23° (range, 3 to 40°) of forward flexion. In total, 22 of 23 patients (96%) experienced increases in range of motion that were maintained at 1 year following treatment. Statistically significant increases in range of motion and clinical function scores were noted; age and gender did not appear to influence the outcomes. Discussion: This device compared favorably to other treatment methods for shoulder stiffness. An orthosis utilizing static progressive stretch was a useful adjunct for the treatment of shoulder stiffness refractory to conventional therapy.


Articles with similar content:

Effectiveness of Negative-Pressure Wound Therapy following Total Hip and Knee Replacements
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 1
Videshnandan Raut, Hosam E. Matar, Nicholas Emms
Kinematic and Kinetic Analysis of the Knee Joint before and after a PCL Retaining Total Knee Replacement during Gait and Single Step Ascent
Journal of Long-Term Effects of Medical Implants, Vol.21, 2011, issue 4
Nikolaos Darras, Dimitrios Mastrokalos, loannis V. Michos, Stergios N. Lallos, Nikolaos E. Efstathopoulos, Alexandros P. Apostolopoulos, Magda Tzomaki
Long-Term Survival of a Flat-on-Flat Total Condylar Knee Arthroplasty Fixed with a Hybrid Cementing Technique for Tibial Components
Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 4
Fabrizio Matassi, Roberto Civinini, Christian Carulli, Massimo Innocenti, Lorenzo Nistri
Treatment of Adhesive Capsulitis of the Shoulder with a Static Progressive Stretch Device: A Prospective, Randomized Study
Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 4
Mahmoud I. Ibrahim, Robert Pivec, Michael A. Mont, Bhaveen V. Kapadia, Qais Naziri, Kimona Issa, Aaron J. Johnson
Risk Factors Associated with Adjacent and Remote- Level Pathologic Vertebral Compression Fracture Following Balloon Kyphoplasty: 2-Year Follow-Up Comparison Versus Conservative Treatment
Journal of Long-Term Effects of Medical Implants, Vol.25, 2015, issue 4
Donald Hohman, Chetan Deshpande, Michael J. Faloon, Conor Dunn, Nicholas Beckloff, Mark Ruoff, Dipak V. Patel