Ethics of Medical Device Safety

巻 18, 発行 2, 2008, pp. 167-174
DOI: 10.1615/JLongTermEffMedImplants.v18.i2.50
Get accessGet access

要約

How safe is safe? The design intent of a medical device is to off er maximum flexibility, and low-cost and fail-safe features. Easily said, these requirements are difficult to deliver in a litigious society where performance standards are uncommon. Medical device manufacturers face challenges as they strive to offer the ultimate in product safety and keep the price affordable for the technology deployed, while making the usability of typically complex products common sense for the operator. As microprocessors are able to assist designers in providing intelligent, multifunctional systems, care must be taken during the design process to balance technological ability with intuitive use. The medical device development process requires rigor that is not often taught to biomedical engineers. Ethical product development requires a process that will be described in this paper using as an example the development of a recent cardiopulmonary perfusion system. However, the same techniques are germane to implantable devices such as cochlear implants. All engineering product development requires trade-off decisions considering how much is too much and how much is too little. Biomedical engineering faculty need to present this ethical dilemma to their students and give them the tools to help decide. However, in the final analysis, the operator of any medical product or installer of any medical device holds the primary responsibility for understanding how to use the system or install the implant in normal use as well as emergent or special situations; the technology is his or her backup in performing the medical professional’s primary job.

によって引用された
  1. UEMURA Kazunori, SUGIMACHI Masaru, Automated Cardiovascular Drug Infusion System to Control Hemodynamics, Advanced Biomedical Engineering, 2, 2013. Crossref

  2. Quintal A., Messier V., Rabasa-Lhoret R., Racine E., A critical review and analysis of ethical issues associated with the artificial pancreas, Diabetes & Metabolism, 45, 1, 2019. Crossref

近刊の記事

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Begell Digital Portal Begellデジタルライブラリー 電子書籍 ジャーナル 参考文献と会報 リサーチ集 価格及び購読のポリシー Begell House 連絡先 Language English 中文 Русский Português German French Spain