Femoral Strain Profiles Under Simulated 3-D Muscle and Joint Loads for Heel Strike, Midstance, and Toe Off

Robert A. Latour
Department of Bioengineering and Materials Science & Engineering, 501 Rhodes Research Center, Clemson University, Clemson, SC 29634.
Michael A. Brattain
Department of Bioengineering and Materials Science & Engineering, 501 Rhodes Research Center, Clemson University, Clemson, SC 29634.

ABSTRACT

A universal static hip joint simulation apparatus was designed to simulate both 3-D joint and 3-D muscle forces for each of the three load-bearing phases of normal gait. The adjustability provided by the apparatus allowed for the consideration of femoral orientation, hip joint contact force, and primary active muscle loads for each simulated activity. Use of this apparatus enables the biomechanical response of the femur to be more fully and accurately determined under a full range of everyday activities. Results demonstrate that the proximal femur experiences significantly higher levels of strain during the activities of toe off and heel strike than during midstance. This evaluation underscores the importance of considering each phase of gait when investigating the biomechanical response of the femur, which should be especially relevant in the design and evaluation of femoral components for hip joint arthroplasty. Future studies are planned for femoral strain evaluation following simulated hip joint replacement. By providing a more complete strain profile evaluation of the femur as a function of implant design, the use of this apparatus should contribute to the development of new femoral component designs for improved patient care.


Articles with similar content:

Design Optimization of Skeletal Hip Implant Cross- Sections Using Finite-Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.19, 2009, issue 4
Sudesh Sivarasu, Pearline Beulah, Lazar Mathew
Failure of Cemented Constrained Acetabular Component at the Bipolar Outer Femoral Head Interface in Revision Hip Arthroplasty
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 1
Paula Stritch, Hosam E. Matar, Nicholas Emms
Clinical Evaluation of a New Total Hip Prosthetic Design: 100 Consecutive Cementless Total Hip Arthroplasties Using Sulzermedica's "Natural Hip" With Two- to Six-Year Clinical and Radiographic Follow-Up
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 1&2
Thomas B. Pace
Proteoglycan-Induced Arthritis: Immune Regulation, Cellular Mechanisms, and Genetics
Critical Reviews™ in Immunology, Vol.23, 2003, issue 3
Tibor T. Glant, Alison Finnegan, Katalin Mikecz
Hemiepiphysiodeses for Guided Growth in Children
Journal of Long-Term Effects of Medical Implants, Vol.24, 2014, issue 2-3
Andreas Karameris, George C. Babis, Ioannis Christogiannis, Kleo Papaparaskeva, George Nomikos, Dimitrios Koulalis, Andreas F. Mavrogenis, Apostolos Papalois, Dimitrios Dovris