Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
International Journal of Fluid Mechanics Research
ESCI SJR: 0.206 SNIP: 0.446 CiteScore™: 0.5

ISSN Imprimer: 2152-5102
ISSN En ligne: 2152-5110

Volumes:
Volume 46, 2019 Volume 45, 2018 Volume 44, 2017 Volume 43, 2016 Volume 42, 2015 Volume 41, 2014 Volume 40, 2013 Volume 39, 2012 Volume 38, 2011 Volume 37, 2010 Volume 36, 2009 Volume 35, 2008 Volume 34, 2007 Volume 33, 2006 Volume 32, 2005 Volume 31, 2004 Volume 30, 2003 Volume 29, 2002 Volume 28, 2001 Volume 27, 2000 Volume 26, 1999 Volume 25, 1998 Volume 24, 1997 Volume 23, 1996 Volume 22, 1995

International Journal of Fluid Mechanics Research

DOI: 10.1615/InterJFluidMechRes.v34.i2.50
pages 159-178

Effect of Restriction and Reynolds Number on the Pressure of Blood of a Stenotic Artery

Dipak Kumar Mandal
Deptartment of Mechanical Engineering, College of Engineering & Management, Kolaghat, P.O: K.T.P.P. Township, Midnapore (E) - 721171, West Bengal, India
Somnath Chakrabarti
Department of Mechanical Engineering, Indian Institute of Engineering Science and Technology Shibpur, Howrah, 711103, West Bengal, India

RÉSUMÉ

Coronary artery disease is the end result of a complex process called atherosclerosis, which is commonly called hardening of the arteries. The pressure of blood in a coronary artery is considered to be one of the important contributors for the formation and progression of atherosclerosis. Therefore, in this paper, the impact of flow Reynolds number and percent stenosis on wall pressure and average pressure of blood near the stenosis in a part of coronary artery is studied considering laminar flow and blood as Newtonian fluid. The two-dimensional steady differential equations for conservation of mass and momentum is solved by finite difference method for Reynolds number ranging from 25 to 375 and percent stenosis from 10 to 90 %. From the study, it is revealed that for all the cases, higher the Reynolds number, higher is the concerned non-dimensional pressure. A sharp variation in dimensionless wall and average pressure has also been noted at the zone of restriction. The variation in non-dimensional wall pressure and average static pressure near the zone of stenosis is higher both for high percent stenosis and low Reynolds number.


Articles with similar content:

Study of Pressure Drop and Flow Characteristics Across Rectangular Stenotic Models
International Journal of Fluid Mechanics Research, Vol.34, 2007, issue 5
Somnath Chakrabarti, Dipak Kumar Mandal
Study on Pressure Drop and Center Line Velocity Distribution Across Cosine Shaped Stenotic Model
International Journal of Fluid Mechanics Research, Vol.36, 2009, issue 4
Ranjan Ganguly, Moloy Kumar Banerjee, Amitava Datta
Analysis of Steady and Physiological Pulsatile Flow Characteristics in an Artery with Various Percentages of Restrictions
International Journal of Fluid Mechanics Research, Vol.42, 2015, issue 3
Nirmal Kumar Manna, Somnath Chakrabarti, P. Goswami, Dipak Kumar Mandal
NUMERICAL INVESTIGATION OF MULTIPHASE FLOW INSIDE A PRESSURE SWIRL ATOMIZER AT THE INITIAL STAGE OF INJECTION
Atomization and Sprays, Vol.28, 2018, issue 5
Alireza Razeghi, Özgür Ertunç
A Computational Study on the Physiologically Realistic Pulsatile Flow through an Eccentric Arterial Stenosis
International Journal of Fluid Mechanics Research, Vol.38, 2011, issue 3
A. K. M. Sadrul Islam, A.B.M. Toufique Hasan, Dipak Kanti Das