The Impact Factor measures the average number of citations received in a particular year by papers published in the journal during the two preceding years. 2017 Journal Citation Reports (Clarivate Analytics, 2018) IF: 1.2 To calculate the five year Impact Factor, citations are counted in 2017 to the previous five years and divided by the source items published in the previous five years. 2017 Journal Citation Reports (Clarivate Analytics, 2018) 5-Year IF: 1.8 The Immediacy Index is the average number of times an article is cited in the year it is published. The journal Immediacy Index indicates how quickly articles in a journal are cited. Immediacy Index: 0.3 The Eigenfactor score, developed by Jevin West and Carl Bergstrom at the University of Washington, is a rating of the total importance of a scientific journal. Journals are rated according to the number of incoming citations, with citations from highly ranked journals weighted to make a larger contribution to the eigenfactor than those from poorly ranked journals. Eigenfactor: 0.00095 The Journal Citation Indicator (JCI) is a single measurement of the field-normalized citation impact of journals in the Web of Science Core Collection across disciplines. The key words here are that the metric is normalized and cross-disciplinary. JCI: 0.28 SJR: 0.341 SNIP: 0.536 CiteScore™:: 1.9 H-Index: 57

Indexed in

DESIGN AND CHARACTERIZATION OF TWIN-FLUID Y-JET ATOMIZERS

Volume 2, Numéro 1, 1992, pp. 45-59
DOI: 10.1615/AtomizSpr.v2.i1.40
Get accessGet access

RÉSUMÉ

Two Y-jet atomizers have been tested using water and two different mineral oils that have the same physical properties as heavy fuel oils (HFO) employed in industrial burners. It has been found that the two-phase flow inside the nozzle can be described by a simplified momentum balance relative to the gas phase. This equation can be used for design purposes. Mean dropsize has been correlated in terms of dimensionless numbers related to the physical properties of the two-phase mixtures and to the operating conditions.

CITÉ PAR
  1. In Wang Kee, Lee Sang Yong, Examination of interfacial shape and onset of slugging of a stratified flow at a combining Y-junction, International Journal of Heat and Fluid Flow, 19, 1, 1998. Crossref

  2. Pacifico Antonio L., Yanagihara Jurandir I., The influence of geometrical and operational parameters on Y-jet atomizers performance, Journal of the Brazilian Society of Mechanical Sciences and Engineering, 36, 1, 2014. Crossref

  3. Lee Sang Ji, Kim Ji Yeop, Hong Jung Goo, Effects of Y-Jet Nozzle Mixing Chamber Length and the GLR on Spatial Asymmetric Spray, ACS Omega, 6, 26, 2021. Crossref

  4. Nazeer Y. H., Ehmann M., Sami M., Gavaises M., Atomization Mechanism of Internally Mixing Twin-Fluid Y-Jet Atomizer, Journal of Energy Engineering, 147, 1, 2021. Crossref

  5. Chen Guang, Fu Cheng, Xu Bingbing, Wu Ying, Lien Fue-Sang, Yee Eugene, Internal mixing air-assisted spray nozzle for large droplets: Experimental measurements and numerical simulations, Journal of Aerosol Science, 165, 2022. Crossref