Volume 47, 2019 Volume 46, 2018 Volume 45, 2017 Volume 44, 2016 Volume 43, 2015 Volume 42, 2014 Volume 41, 2013 Volume 40, 2012 Volume 39, 2011 Volume 38, 2010 Volume 37, 2009 Volume 36, 2008 Volume 35, 2007 Volume 34, 2006 Volume 33, 2005 Volume 32, 2004 Volume 31, 2003 Volume 30, 2002 Volume 29, 2001 Volume 28, 2000 Volume 27, 1999 Volume 26, 1998 Volume 25, 1997 Volume 24, 1996 Volume 23, 1995

Critical Reviews™ in Biomedical Engineering

DOI: 10.1615/CritRevBiomedEng.v28.i12.280
pages 165-171

Ultra-Low-Noise Instrumentation and Computer-Based Data Acquisition and Processing System for Obtaining a Noninvasive and Intrauterine Catheter Fetal Electrocardiogram

Steven L. Horner
Bucknell University, Department of Electrical Engineering, Lewisburg, PA 17837; and University of Tennessee Medical Center, Department of Obstetrics and Gynecology, 1924 Alcoa Highway, Knoxville, TN 37920
William M. Holls
University of Tennessee Medical Center, Department of Obstetrics and Gynecology, 1924 Alcoa Highway, Knoxville, TN 37920

RÉSUMÉ

A fetal electrocardiogram (FECG) from the abdominal surface will be from 20 mVpp to immeasurable. The intrauterine catheter signal will be from 50 mVpp - to unmeasureable and will be corrupted with a significant direct current component of 10 to 200 mV. For electrophysiological information to be obtained from the abdominal and intrauterine catheter signals, the signals must be in a 0.05 to 100.0 Hz bandwidth. Because typical adult electrocardiogram systems have a noise specification of 5 to 10 mVpp from instrumentation, these systems are unacceptable for obtaining a FECG via the intrauterine catheter or noninvasively. Therefore, custom instrumentation has been developed with a noise specification of approximately 1.5 mVpp in a 0.05 to 100.0 Hz bandwidth.
Design details of the custom instrumentation will be presented along with a laptop computer based data acquisition and signal processing system using Lab VIEW. In addition, clinical data from the intrauterine catheter and noninvasive abdominal wall are presented to determine the feasibility of obtaining a FECG via the custom instrumentation. Clinical data obtained and documented indicates that after maternal electrocardiogram cancellation, a FECG with a good signal-to-noise ratio can be obtained in a diagnostic bandwidth of 0.05 to 100.0 Hz. Because the diagnostic bandwidth is preserved, electrophysiological information can be determined along with heart rate.


Articles with similar content:

Ballistocardiogram Correction in Simultaneous EEG/ fMRI Recordings: A Comparison of Average Artifact Subtraction and Optimal Basis Set Methods Using Two Popular Software Tools
Critical Reviews™ in Biomedical Engineering, Vol.42, 2014, issue 2
James P. Reilly, Amabilis H. Harrison, Michael D. Noseworthy, John F. Connolly
NATURAL CONVECTION OF POWER LAW FLUIDS FROM A VERTICAL PLATE WITH UNIFORM SURFACE HEAT FLUX
International Heat Transfer Conference 5, Vol.4, 1974, issue
J. L. S. Chen, A. Boehm
A NOVEL IMPLEMENTATION OF SNR ESTIMATION BASED ON LARGE SCALE PROGRAMMABLE LOGIC CIRCUITS
Telecommunications and Radio Engineering, Vol.78, 2019, issue 15
W. Wang, Zh. Shen, S. N. Shulga, S. Wang, Yu. Zheng, P. Wang, H. Zhang, G. Ren
Development of Fiber Optic and Electrochemical pH Sensors to Monitor Brain Tissue
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 1&2
Julie Hamilton, Kerry Bettencourt, Robert Glass, Peter Krulevitch, Sheila A. Grant
Dietary Cured Meat and the Risk of Adult Glioma: A Meta-Analysis of Nine Observational Studies
Journal of Environmental Pathology, Toxicology and Oncology, Vol.22, 2003, issue 2
Lamar Wheeler, Michael Huncharek, Bruce Kupelnick