Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Critical Reviews™ in Biomedical Engineering
SJR: 0.207 SNIP: 0.376 CiteScore™: 0.79

ISSN Imprimer: 0278-940X
ISSN En ligne: 1943-619X

Volumes:
Volume 47, 2019 Volume 46, 2018 Volume 45, 2017 Volume 44, 2016 Volume 43, 2015 Volume 42, 2014 Volume 41, 2013 Volume 40, 2012 Volume 39, 2011 Volume 38, 2010 Volume 37, 2009 Volume 36, 2008 Volume 35, 2007 Volume 34, 2006 Volume 33, 2005 Volume 32, 2004 Volume 31, 2003 Volume 30, 2002 Volume 29, 2001 Volume 28, 2000 Volume 27, 1999 Volume 26, 1998 Volume 25, 1997 Volume 24, 1996 Volume 23, 1995

Critical Reviews™ in Biomedical Engineering

DOI: 10.1615/CritRevBiomedEng.v30.i123.60
pages 99-130

Methods for Assessing Adequacy of Anesthesia

Mark van Gils
VTT Information Technology, Tampere, Finland
Ilkka Korhonen
VTT Information Technology, Tampere, Finland
Arvi Yli-Hankala
Department of Anaesthesiology. Medical School, University of Tampere, and Department of Anaesthesia, Tampere University Hospital, Tampere, Finland

RÉSUMÉ

Assessing adequacy of anesthesia requires evaluation of its components: hypnosis, analgesia, and neuromuscular transmission. In order to do this, many methods have been developed that process signals representing different modalities. Assessment of hypnosis requires cortical measures of the central nervous system (CNS); methods that assess analgesia concentrate on subcortical and spinal levels of the CNS; and neuromuscular transmission is a peripheral phenomenon. This article presents an overview of the current state of methods available for measuring each of these components. We conclude that, whereas important gains have been made in the area of assessment of hypnosis, mainly owing to the advancement of methods using EEG and auditory evoked potentials, and whereas neuromuscular transmission can be objectively monitored using motor nerve stimulation, assessment of analgesia still contains many challenges.


Articles with similar content:

Procedures for Evaluating the Adequacy of Anesthesia
Critical Reviews™ in Biomedical Engineering, Vol.45, 2017, issue 1-6
Mark van Gils, Arvi Yli-Hankala, Ilkka Korhonen
A Review on Functional Electrical Stimulation in Tetraplegic Patients to Restore Hand Function
Journal of Long-Term Effects of Medical Implants, Vol.27, 2017, issue 2-4
Tyler C. Wind, Elizabeth V. Jones, Richard Edlich, Gregory G. Degnan
Functional Electrical Stimulation in Tetraplegic Patients to Restore Hand Function
Journal of Long-Term Effects of Medical Implants, Vol.12, 2002, issue 3
Tyler C. Wind, Richard Edlich, Gregory G. Degnan
Design, Control, and Sensory Feedback of Externally Powered Hand Prostheses: A Literature Review
Critical Reviews™ in Biomedical Engineering, Vol.41, 2013, issue 2
Aimee Cloutier, James Yang
Bioengineering Assessment of Acupuncture, Part 5: Cerebral Near-Infrared Spectroscopy
Critical Reviews™ in Biomedical Engineering, Vol.34, 2006, issue 6
Gerhard Litscher