Volume 51, 2020 Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.v41.i5.40
pages 531-558

Dimensionless Local and Average Boiling Heat Transfer Correlation for Saturated Liquids

Mihir Kumar Das
School of Mechanical Sciences, Indian Institute of Technology Bhubaneswar, Odisha 752050, India
Satish C. Gupta
Department of Chemical Engineering, University of Roorkee, Roorkee - 247667 India
V. K. Agarwal
Chemical Engineering Department, Indian Institute of Technology Roorkee, Roorkee - 247667

RÉSUMÉ

The present study is an experimental investigation on nucleate pool boiling of saturated liquids namely, distilled water, methanol, and iso-propanol over a plain copper heating tube at atmospheric and sub-atmospheric pressures. The study includes the effect of operating parameters, i.e., heat flux and pressure on the boiling heat transfer coefficient of saturated liquids on a copper heating tube. The boiling heat transfer coefficient is determined locally at the bottom, two sides and at the top position of the heating tube and a dimensionless equation of the form h*ψ/h*ψ,1= [(a+b cos ψ)/ (a+b cos ψ)1](ρ/ρ1)0.32 is established for prediction of the local boiling heat transfer coefficient at different pressures. Further, a dimensional equation, h = Cq0.7ρ0.32 , is established for determination of the average boiling heat transfer coefficient of saturated liquids on a plain copper heating tube. The dimensionless correlations of earlier investigators are tested with experimental data of the present investigation for the sake of comparison. Further, a dimensionless correlation of the form: Nu*B = Csf(Pe*B)0.7(Kp)0.7(Pr)−0.67 is proposed. The correlation is found to fit experimental data of the present investigation within a maximum error of ±6.


Articles with similar content:

SODIUM NATURAL CONVECTION FROM A VERTICAL PLATE
International Heat Transfer Conference 6, Vol.5, 1978, issue
N. Sheriff, N. W. Davies
POOL BOILING HEAT TRANSFER AND SIZE OF ACTIVE NUCLEATION CENTERS FOR HORIZONTAL PLATES WITH DIFFERENT SURFACE ROUGHNESS
International Heat Transfer Conference 6, Vol.1, 1978, issue
M. Salem , Dieter Gorenflo, K. Bier , Y. Tanes
Some Characteristics of Falling Liquid Film Flow Boiling
International Heat Transfer Conference 12, Vol.43, 2002, issue
Zhangyan Jiang, Zhiwei Tang, Chong Fang Ma
A THEORETICAL CONSIDERATION FOR PREDICTING HEAT TRANSFER CHARACTERISTICS OF A TUBE BANK FROM MEASUREMENTS WITH A SINGLE TEST TUBE
International Heat Transfer Conference 8, Vol.6, 1986, issue
T. Fujii, Motoo Fujii, R. Sato
POOL BOILING HEAT TRANSFER ON HORIZONTAL STEEL TUBES WITH DIFFERENT DIAMETERS
Multiphase Science and Technology, Vol.12, 2000, issue 3&4
Dieter Gorenflo, Andrea Luke, Paul Kaupmann