Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Heat Transfer Research
Facteur d'impact: 0.404 Facteur d'impact sur 5 ans: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimer: 1064-2285
ISSN En ligne: 2162-6561

Volumes:
Volume 51, 2020 Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.v41.i7.60
pages 769-786

Effect of Internal Rib Configurations on the Discharge Coefficient of a 30°-Inclined Film Cooling Hole

Christian Heneka
Institute of Thermal Turbomachinery (ITS), Karlsruhe Institute of Technology (KIT), Kaiserstrasse 12, 76131 Karlsruhe, Germany
Achmed Schulz
Institut fuer Thermische Stroemungsmaschinen (ITS), Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe, Germany
Hans-Jorg Bauer
Institut fuer Thermische Stroemungsmaschinen (ITS), Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe, Germany

RÉSUMÉ

Turbulators like ribs inside turbine blade coolant channels are known to improve convective cooling but at the same time could affect external film cooling. The effect of rib placement and internal crossflow conditions on the discharge behavior of a film cooling configuration is the main focus of the present experimental study. Discharge coefficients of 30o-inclined cylindrical film cooling holes with a length to diameter ratio of 6 are presented. Measurements have been performed varying the position of ribs oriented normally to the internal crossflow direction as well as the crossflow Mach number at the hole inlet (Mac = 0−0.3). Sharp-edged quadratic ribs with a height equal to the hole diameter and a rib pitch to height ratio of 10 are used. The external crossflow Mach number has been kept constant at Mam = 0.3. The internal and the external flow have been oriented parallel and perpendicular to each other. The lateral hole angle has been set to 0°, 45°, and 90°. The analysis of the results identifies the deflection of the coolant flow entering the hole as the decisive parameter for describing the effect of crossflow and ribs inside the internal channel on the discharge coefficient. The obtained extensive amount of data is used for the development of a discharge coefficient correlation taking into account the combined effect of internal crossflow Mach number, orientation of internal crossflow and hole axis, and rib configurations.