Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Heat Transfer Research
Facteur d'impact: 0.404 Facteur d'impact sur 5 ans: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimer: 1064-2285
ISSN En ligne: 2162-6561

Volumes:
Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.v42.i2.40
pages 143-164

Influence of Internal Cyclone Flow on Adiabatic Film Cooling Effectiveness

Andreas Lerch
Institute of Gas Turbines and Aerospace Propulsion, Technische Universität Darmstadt, 64287 Darmstadt, Germany
Heinz-Peter Schiffer
Institute of Gas Turbines and Aerospace Propulsion, Technische Universität Darmstadt, 64287 Darmstadt, Germany

RÉSUMÉ

The adiabatic film cooling effectiveness on the surface of a symmetrical blade model was measured for eight cylindrical, 59° inclined cooling holes. The holes were fed with different flow types using a cylindrical leading-edge channel. Two configurations were compared: on the one hand, a leading-edge channel flow without swirl (datum configuration), using a sharp-edged inlet; on the other hand, a new cyclone cooling configuration with a positive swirl. The experiments were carried out using the calibrated ammonia diazo technique. The blowing ratios were varied between 0.6 and 1.2, and the film cooling discharge was set to either 20% or 50%. For all these operation points, multiple experiments were conducted and combined using a weighting average method to produce a high full-range resolution. The lateral and area-averaged adiabatic effectiveness is presented up to 45D downstream of the cooling holes. The measurements show a higher area-averaged effectiveness immediately downstream of the cooling holes when using the cyclone cooling configuration. This is due to nonsymmetric flow structures inside the cooling holes. Further downstream, however, it decreases faster. With a low film cooling discharge and rising blowing ratios, these effects are more pronounced.


Articles with similar content:

INFLUENCE OF INTERNAL CYCLONE FLOW ON ADIABATIC FILM COOLING EFFECTIVENESS
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2009, issue
Heinz-Peter Schiffer, Andreas Lerch
FILM COOLING FROM TWO ROWS OF HOLES WITH OPPOSITE ORIENTATION ANGLES: INJECTANT BEHAVIORS
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Joon Ahn, In Sung Jung, Joon Sik Lee
FILM TEMPERATURE AND EFFECTIVENESS MEASUREMENTS ON A CYLINDRICAL LEADING EDGE FILM COOLING MODEL
International Heat Transfer Conference 11, Vol.18, 1998, issue
Shuye Teng, Je-Chin Han, Dong Kee Sohn
Distributions of Local Heat Transfer Coefficient on Surfaces with Solid and Perforated Ribs
Journal of Enhanced Heat Transfer, Vol.5, 1998, issue 1
S. C. Lau, R. T. Kukreja
EFFECT OF ANTI-VORTEX HOLE ANGLE ON THE FILM COOLING EFFECTIVENESS
Heat Transfer Research, Vol.48, 2017, issue 6
Jae Su Kwak, Younggi Moon, Soon Sang Park, Jung Shin Park