Abonnement à la biblothèque: Guest
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections
Heat Transfer Research
Facteur d'impact: 1.199 Facteur d'impact sur 5 ans: 1.155 SJR: 0.267 SNIP: 0.503 CiteScore™: 1.4

ISSN Imprimer: 1064-2285
ISSN En ligne: 2162-6561

Volumes:
Volume 51, 2020 Volume 50, 2019 Volume 49, 2018 Volume 48, 2017 Volume 47, 2016 Volume 46, 2015 Volume 45, 2014 Volume 44, 2013 Volume 43, 2012 Volume 42, 2011 Volume 41, 2010 Volume 40, 2009 Volume 39, 2008 Volume 38, 2007 Volume 37, 2006 Volume 36, 2005 Volume 35, 2004 Volume 34, 2003 Volume 33, 2002 Volume 32, 2001 Volume 31, 2000 Volume 30, 1999 Volume 29, 1998 Volume 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2014006686
pages 399-415

THERMODYNAMIC ANALYSIS AND COMPARISON OF SINGLE EFFECT WATER−LITHIUM BROMIDE ABSORPTION HEAT TRANSFORMER UNDER THE HIGH- AND LOW-TEMPERATURE CONDITIONS

Zhaolong Hao
Institute of Chemical Engineering, Dalian University of Technology, Dalian 116012, China
Xuehu Ma
Liaoning Key Laboratory of Clean Utilization of Chemical Resources, Institute of Chemical Engineering, Dalian University of Technology, Dalian 116024, China
Zhong Lan
Institute of Chemical Engineering, Liaoning Key Laboratory of Clean Utilization of Chemical Resources, Dalian University of Technology, Dalian, China

RÉSUMÉ

In this paper, the thermodynamic analysis and comparison of the performance of a single-effect water−lithium bromide absorption heat transformer in high- and low-temperature conditions is presented. The energy, exergy, and the energy level difference methods have been used to analyze the performance of the system for both conditions in detail. The analysis involves the effect of the gross temperature lift (GTL) on the coefficient of performance (COP), exergetic efficiency, exergy destruction, and energy level difference for all the components in high- and low-temperature conditions. The results indicate that the exergetic efficiency for the high-temperature conditions varies between 0.8 and 0.9 which is higher and more stable than that for the low-temperature conditions varying between 0.4 and 0.7. The absorber and the solution heat exchanger are the components wherein the irreversibilities for the high-temperature conditions are higher than those for the low-temperature conditions at some GTL. This means that these components should be carefully designed and optimized for the high-temperature conditions. Furthermore, the energy level difference analysis methodology used here is found to be a powerful and systematic tool in disclosing the mechanism of exergy destruction in energy conversion processes.


Articles with similar content:

AN ASSESSMENT OF WORKING-FLUID MIXTURES USING SAFT-VR MIE FOR USE IN ORGANIC RANKINE CYCLE SYSTEMS FOR WASTE-HEAT RECOVERY
Computational Thermal Sciences: An International Journal, Vol.6, 2014, issue 4
Christos Markides, Aly I. Taleb, Andrew J. Haslam, Oyeniyi A. Oyewunmi
THERMAL PROCESSES OPERATIONAL OPTIMIZATION THROUGH AVOIDABLE AND UNAVOIDABLE EXERGY DESTRUCTION EVALUATION, A CASE STUDY
Second Thermal and Fluids Engineering Conference, Vol.15, 2017, issue
Renato S. A. Bello, Jorge Kurita, Fabio D. Mendoza, Dario Alviso
EXERGY ANALYSIS AND OPTIMUM THERMOECONOMICS OF DUAL PRESSURE WASTE HEAT RECOVERY SYSTEMS FOR DIESEL SHIPS
Energy and Environment, 1995, Vol.0, 1995, issue
LiJun Xu, AMin Yu, Song Zhou
AN EXERGY ANALYSIS OF THE LiBr-WATER ABSORPTION REFRIGERATING CYCLE
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Yoshinori Hisazumi, Xiao Wang, Hitoshi Asano, Terushige Fujii
COMBINED HEAT AND MASS TRANSFER EST A DEHUMIDIFIER − THE BASIS OF LOW ENERGY AIR CONDITIONING TAILORED FOR HUMAN COMFORT
International Heat Transfer Conference 9, Vol.5, 1990, issue
Albert Shaw, R.E. Luxton