Abonnement à la biblothèque: Guest
Journal of Long-Term Effects of Medical Implants

Publication de 4  numéros par an

ISSN Imprimer: 1050-6934

ISSN En ligne: 1940-4379

SJR: 0.184 SNIP: 0.485 CiteScore™:: 1.1 H-Index: 39

Indexed in

The Biomechanical Effects of Fatigue on the Porcine Bioprosthetic Heart Valve

Volume 11, Numéro 3&4, 2001, 17 pages
DOI: 10.1615/JLongTermEffMedImplants.v11.i34.100
Get accessGet access

RÉSUMÉ

Characterization of the mechanisms of degeneration of porcine bioprosthetic heart valves (BHV) during long-term cyclic loading is required for predicting and ultimately preventing their failure. Isolation of purely mechanical effects from host biological ones is a necessary first step in understanding the fatigue process as a whole. Thus, in this review we focus on mechanical factors alone as a means of isolating their role in altering biomechanical properties and ultimately their contribution to the fatigue damage process. Mechanical evaluations included tension controlled biaxial, 3-point flexural, and uniaxial failure tests performed on cuspal tissue following 0, 50, 100, 200, and 300 × 106 in vitro accelerated test cycles. Overall, biaxial mechanical results indicate a decreasing radial extensibility that can be explained by stiffening of the effective collagen fiber network as well as a small decrease in the splay of the collagen fibers. Moreover, these results suggest that the loss in flexural rigidity with fatigue that we have previously measured (ASAIO 1999; 45:59−63) may not be because of loss of collagen stiffness alone, but also to fiber debonding and degradation of the amorphous extracellular matrix. We discuss the implications of these results that point toward the development of chemical-treatment methods that seek to maintain the integrity of the amorphous extracellular matrix to ultimately extend BHV long-term durability.

CITÉ PAR
  1. Dassow Constanze, Armbruster Caroline, Friedrich Christian, Smudde Eva, Guttmann Josef, Schumann Stefan, A method to measure mechanical properties of pulmonary epithelial cell layers, Journal of Biomedical Materials Research Part B: Applied Biomaterials, 101, 7, 2013. Crossref

  2. Einstein Daniel R. , Kunzelman Karyn S. , Reinhall Per G. , Nicosia Mark A. , Cochran Richard P. , The Relationship of Normal and Abnormal Microstructural Proliferation to the Mitral Valve Closure Sound , Journal of Biomechanical Engineering, 127, 1, 2005. Crossref

  3. Sellaro Tiffany L., Hildebrand Daniel, Lu Qijin, Vyavahare Naren, Scott Michael, Sacks Michael S., Effects of collagen fiber orientation on the response of biologically derived soft tissue biomaterials to cyclic loading, Journal of Biomedical Materials Research Part A, 80A, 1, 2007. Crossref

  4. Chandran K. B., Heart Valve Prostheses, in Encyclopedia of Medical Devices and Instrumentation, 2006. Crossref

  5. Sun Wei, Sacks Michael, Fulchiero Gregory, Lovekamp Joshua, Vyavahare Naren, Scott Michael, Response of heterograft heart valve biomaterials to moderate cyclic loading, Journal of Biomedical Materials Research, 69A, 4, 2004. Crossref

  6. Robinson Paul S., Tranquillo Robert T., Planar Biaxial Behavior of Fibrin-Based Tissue-Engineered Heart Valve Leaflets, Tissue Engineering Part A, 15, 10, 2009. Crossref

  7. Anssari-Benam Afshin, Is the time-dependent behaviour of the aortic valve intrinsically quasi-linear?, Mechanics of Time-Dependent Materials, 18, 2, 2014. Crossref

  8. Michael Lee J., Tissue Mechanics, in Wiley Encyclopedia of Biomedical Engineering, 2006. Crossref

  9. Helmus M.N, Cunanan C.M, Mechanical and bioprosthetic heart valves, in Biomaterials for Artificial Organs, 2011. Crossref

  10. Mirnajafi Ali, Zubiate Brett, Sacks Michael S., Effects of cyclic flexural fatigue on porcine bioprosthetic heart valve heterograft biomaterials, Journal of Biomedical Materials Research Part A, 94A, 1, 2010. Crossref

  11. Abbasi Mostafa, Azadani Ali N., Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion, Journal of Biomechanics, 48, 13, 2015. Crossref

  12. Friebe Vincent M., Mikulis Brandon, Kole Sourav, Ruffing Christy S., Sacks Michael S., Vyavahare Naren R., Neomycin enhances extracellular matrix stability of glutaraldehyde crosslinked bioprosthetic heart valves, Journal of Biomedical Materials Research Part B: Applied Biomaterials, 99B, 2, 2011. Crossref

  13. Borovetz Harvey S., Burke John F., Chang Thomas Ming Swi, Colas André, Cranin A. Norman, Curtis Jim, Gemmell Cynthia H., Griffith Bartley P., Hallab Nadim James, Heller Jorge, Hoffman Allan S., Jacobs Joshua J., Ideker Ray, Katz J. Lawrence, Kennedy Jack, Lemons Jack E., Malchesky Paul S., Morgan Jeffery R., Padera Robert E., Patel Anil S., Reffojo Miguel F., Roby Mark S., Rohr Thomas E., Schoen Frederick J., Sefton Michael V., Sheridan Robert T., Smith Dennis C., Spelman Francis A., Tarcha Peter J., Tomapkins Ronald G., Venugopalan Ramakrishna, Wagner William R., Yager Paul, Yarmush Martin L., Application of Materials in Medicine, Biology, and Artificial Organs, in Biomaterials Science, 1996. Crossref

  14. Rim Yonghoon, McPherson David D., Kim Hyunggun, Effect of Congenital Anomalies of the Papillary Muscles on Mitral Valve Function, Journal of Medical and Biological Engineering, 35, 1, 2015. Crossref

  15. Lee Chi H, Physiological variables involved in heart valve substitute calcification, Expert Opinion on Biological Therapy, 9, 8, 2009. Crossref

  16. Sacks Michael S., Biomechanics of engineered heart valve tissues, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society, 2006. Crossref

  17. Simonato Matheus, Azadani Ali N., Webb John, Leipsic Jonathon, Kornowski Ran, Vahanian Alec, Wood David, Piazza Nicolo, Kodali Susheel, Ye Jian, Whisenant Brian, Gaia Diego, Aziz Mina, Pasala Tilak, Mehilli Julinda, Wijeysundera Harindra C., Tchetche Didier, Moat Neil, Teles Rui, Petronio Anna Sonia, Hildick-Smith David, Landes Uri, Windecker Stephan, Arbel Yaron, Mendiz Oscar, Makkar Raj, Tseng Elaine, Dvir Danny, In vitro evaluation of implantation depth in valve-in-valve using different transcatheter heart valves, EuroIntervention, 12, 7, 2016. Crossref

  18. Jahnavi S, Saravanan U, Arthi N, Bhuvaneshwar G S, Kumary T V, Rajan S, Verma R S, Biological and mechanical evaluation of a Bio-Hybrid scaffold for autologous valve tissue engineering, Materials Science and Engineering: C, 73, 2017. Crossref

  19. Azadani Ali N., Reardon Michael, Simonato Matheus, Aldea Gabriel, Nickenig Georg, Kornowski Ran, Dvir Danny, Effect of transcatheter aortic valve size and position on valve-in-valve hemodynamics: An in vitro study, The Journal of Thoracic and Cardiovascular Surgery, 153, 6, 2017. Crossref

  20. Högerle Benjamin A., Schneider Maria, Sudrow Katrin, Souidi Naima, Stolk Meaghan, Werner Isabella, Biermann Anna, Brockbank Kelvin G.M., Stock Ulrich A., Seifert Martina, Effects on human heart valve immunogenicity in vitro by high concentration cryoprotectant treatment , Journal of Tissue Engineering and Regenerative Medicine, 12, 2, 2018. Crossref

  21. Sacks Michael S., Schoen Frederick J., Collagen fiber disruption occurs independent of calcification in clinically explanted bioprosthetic heart valves, Journal of Biomedical Materials Research, 62, 3, 2002. Crossref

  22. Hu Yanfei, Su Xin, Lei Yang, Wang Yunbing, A novel anti-calcification method for bioprosthetic heart valves using dopamine-modified alginate, Polymer Bulletin, 76, 3, 2019. Crossref

  23. Sritharan Deepa, Fathi Parinaz, Weaver Jason D., Retta Stephen M., Wu Changfu, Duraiswamy Nandini, Impact of Clinically Relevant Elliptical Deformations on the Damage Patterns of Sagging and Stretched Leaflets in a Bioprosthetic Heart Valve, Cardiovascular Engineering and Technology, 9, 3, 2018. Crossref

  24. Anssari-Benam Afshin, Screen Hazel R.C., Bucchi Andrea, Insights into the micromechanics of stress-relaxation and creep behaviours in the aortic valve, Journal of the Mechanical Behavior of Biomedical Materials, 93, 2019. Crossref

  25. Li Richard L., Russ Jonathan, Paschalides Costas, Ferrari Giovanni, Waisman Haim, Kysar Jeffrey W., Kalfa David, Mechanical considerations for polymeric heart valve development: Biomechanics, materials, design and manufacturing, Biomaterials, 225, 2019. Crossref

Prochains articles

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections Prix et politiques d'abonnement Begell House Contactez-nous Language English 中文 Русский Português German French Spain