A Two-Year Prospective and Retrospective Multi-Center Study of the TriboFit® Hip System

Volume 19, Numéro 2, 2009, pp. 149-155
DOI: 10.1615/JLongTermEffMedImplants.v19.i2.60
Get accessGet access

RÉSUMÉ

The first 50 cases using a polycarbonate-urethane acetabular component in the TriboFit® Hip System for human hip reconstruction were reviewed. The average follow-up for cases not revised or deceased prior to 24 months was 28.0 months. The clinical results were similar to those reported in the literature for the same indications and follow-up. Therefore, with 2 to 4 years follow-up, it can be concluded that the TriboFit® Hip System is as safe and effective for use as a hip replacement system in femoral neck fracture patients as traditional hemiarthroplasty systems, and in osteoarthritis patients as a total hip system made of traditional bearing materials.

CITÉ PAR
  1. Sonntag R., Reinders J., Kretzer J.P., What’s next? Alternative materials for articulation in total joint replacement, Acta Biomaterialia, 8, 7, 2012. Crossref

  2. Moroni Antonio, Hoque Martha, Waddell James P., Russell Thomas A., Wippermann Burkhard, DiGiovanni Gary, Surgical treatment and management of hip fracture patients, Archives of Orthopaedic and Trauma Surgery, 134, 2, 2014. Crossref

  3. St. John Kenneth R., The use of polyurethane materials in the surgery of the spine: a review, The Spine Journal, 14, 12, 2014. Crossref

  4. St. John Kenneth R., The use of compliant layer prosthetic components in orthopedic joint repair and replacement: A review, Journal of Biomedical Materials Research Part B: Applied Biomaterials, 102, 6, 2014. Crossref

  5. Gabarre Sergio, Herrera Antonio, Mateo Jesús, Ibarz Elena, Lobo-Escolar Antonio, Gracia Luis, Study of the Polycarbonate-Urethane/Metal Contact in Different Positions during Gait Cycle, BioMed Research International, 2014, 2014. Crossref

  6. Elsner Jonathan J., Shemesh Maoz, Mezape Yoav, Levenshtein Mario, Hakshur Keren, Shterling Avi, Linder-Ganz Eran, Eliaz Noam, Long-term evaluation of a compliant cushion form acetabular bearing for hip joint replacement: A 20 million cycles wear simulation, Journal of Orthopaedic Research, 29, 12, 2011. Crossref

  7. Kurtz Steven M., Ong Kevin, Contemporary Total Hip Arthroplasty: Alternative Bearings, in UHMWPE Biomaterials Handbook, 2016. Crossref

  8. Morlock M.M., Bishop N., Kaddick C., Welche Hüftgelenkgleitpaarung für welchen Patienten?, Der Orthopäde, 40, 12, 2011. Crossref

  9. Grieco Preston W., Pascal Scott, Newman Jared M., Shah Neil V., Stroud Sarah G., Sheth Neil P., Maheshwari Aditya V., New alternate bearing surfaces in total hip arthroplasty: A review of the current literature, Journal of Clinical Orthopaedics and Trauma, 9, 1, 2018. Crossref

  10. Van Susante Job L C, Verdonschot Nico, Bom L Paul A, Tomaszewski Pawel, Campbell Pat, Ebramzadeh Edward, Schreurs B Wim, Lessons learnt from early failure of a patient trial with a polymer-on-polymer resurfacing hip arthroplasty, Acta Orthopaedica, 89, 1, 2018. Crossref

  11. Biant Leela C, Gascoyne Trevor C, Bohm Eric R, Moran Matthew, Retrieval analysis of a failed TriboFit polycarbonate urethane acetabular buffer, Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 230, 3, 2016. Crossref

  12. Lazic Stefan, Kellett Catherine, Afzal Irrum, Mohan Rajan, Killampalli Vijay, Field Richard E, Three-year results of a polycarbonate urethane acetabular bearing in total hip arthroplasty, HIP International, 30, 3, 2020. Crossref

  13. Eliaz Noam, Hakshur Keren, Fundamentals of Tribology and the Use of Ferrography and Bio-Ferrography for Monitoring the Degradation of Natural and Artificial Joints, in Degradation of Implant Materials, 2012. Crossref

  14. Cadossi M., Chiarello E., Savarino L., Tedesco G., Baldini N., Faldini C., Giannini S., A comparison of hemiarthroplasty with a novel polycarbonate–urethane acetabular component for displaced intracapsular fractures of the femoral neck, The Bone & Joint Journal, 95-B, 5, 2013. Crossref

  15. Molinari Giampaolo, Galmarini Valter, Ferrara Fabrizio, Capelli Roberto, Treatment of hip fractures in the elderly with the “TriboFit” System: retrospective review of our experience, Lo Scalpello - Otodi Educational, 35, 2, 2021. Crossref

  16. Rajpura A., Kendoff D., Board T. N., The current state of bearing surfaces in total hip replacement, The Bone & Joint Journal, 96-B, 2, 2014. Crossref

Prochains articles

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portail numérique Bibliothèque numérique eBooks Revues Références et comptes rendus Collections Prix et politiques d'abonnement Begell House Contactez-nous Language English 中文 Русский Português German French Spain