Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
International Journal of Fluid Mechanics Research
ESCI SJR: 0.206 SNIP: 0.446 CiteScore™: 0.5

ISSN Imprimir: 2152-5102
ISSN En Línea: 2152-5110

Volumes:
Volumen 46, 2019 Volumen 45, 2018 Volumen 44, 2017 Volumen 43, 2016 Volumen 42, 2015 Volumen 41, 2014 Volumen 40, 2013 Volumen 39, 2012 Volumen 38, 2011 Volumen 37, 2010 Volumen 36, 2009 Volumen 35, 2008 Volumen 34, 2007 Volumen 33, 2006 Volumen 32, 2005 Volumen 31, 2004 Volumen 30, 2003 Volumen 29, 2002 Volumen 28, 2001 Volumen 27, 2000 Volumen 26, 1999 Volumen 25, 1998 Volumen 24, 1997 Volumen 23, 1996 Volumen 22, 1995

International Journal of Fluid Mechanics Research

DOI: 10.1615/InterJFluidMechRes.v35.i6.50
pages 570-780

Steady and Unsteady Flow Investigations on the Effect of Different Number of Diffuser Vanes

Ning He
SPMP, Shanghai Port Machinary LTD, Shanghai, P.R. China

SINOPSIS

This paper presents a computational analysis of a high-speed centrifugal compressor stage where emphasis is focused on both the steady and unsteady flow investigations and on the effect of different number of diffuser vanes on the stage operating range. The simulations were carried out for a centrifugal stage with a backswept impeller and several diffusers with 11, 22 and 33 vanes. For the steady simulations, an averaging approach was used at the interface between the impeller and the diffuser. For the unsteady simulations, geometry scaling was used to deal with the problem of unequal pitch. As the number of diffuser vanes was increased, the pressure recovery coefficient in the semi-vaneless space at surge condition was found to reduce. Also, as the number of diffuser vanes was increased, the flow distortion became more pronounced in the vaneless and semi-vaneless space. It is proposed that this more distorted flow is harmful to the pressure recovery in the semi-vaneless space giving stages with more diffuser vanes narrower flow ranges. It was also found that the diffuser area ratio is not the dominant factor influencing the flow range when the number of diffuser vanes changes.


Articles with similar content:

Steady and Unsteady Analysis of the Effects of Radial Gap Size in a Centrifugal Compressor Stage
International Journal of Fluid Mechanics Research, Vol.34, 2007, issue 1
Ning He
FRONT BULKHEAD UPSTREAM EFFECT ON INLET IGV COMPRESSOR FLOW OF MS5002B GAS TURBINE
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2009, issue
Djamel Chekerker, Rabah Dizene
EXPERIMENTAL INVESTIGATION OF TURNING FLOW EFFECTS ON INNOVATIVE TRAILING EDGE COOLING CONFIGURATIONS WITH ELLIPTIC PIN FINS
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2009, issue
Francesco Simonetti, Carlo Carcasci
METHOD FOR DETERMINATION OF AXIAL COMPRESSOR PARAMETERS AT THE BASIC POINTS OF STALLING BRANCH CHARACTERISTICS
TsAGI Science Journal, Vol.40, 2009, issue 3
R. M. Fedorov, Leonid Dmitrievich Kolesinsky
Cavitating flow around a tandem of 2D hydrofoils: high-speed imaging and PIV measurements
ICHMT DIGITAL LIBRARY ONLINE, Vol.0, 2018, issue
Mikhail V. Timoshevskiy, Dmitriy M. Markovich, Konstantin S. Pervunin