Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Journal of Enhanced Heat Transfer
Factor de Impacto: 0.562 Factor de Impacto de 5 años: 0.605 SJR: 0.175 SNIP: 0.361 CiteScore™: 0.33

ISSN Imprimir: 1065-5131
ISSN En Línea: 1026-5511

Volumes:
Volumen 27, 2020 Volumen 26, 2019 Volumen 25, 2018 Volumen 24, 2017 Volumen 23, 2016 Volumen 22, 2015 Volumen 21, 2014 Volumen 20, 2013 Volumen 19, 2012 Volumen 18, 2011 Volumen 17, 2010 Volumen 16, 2009 Volumen 15, 2008 Volumen 14, 2007 Volumen 13, 2006 Volumen 12, 2005 Volumen 11, 2004 Volumen 10, 2003 Volumen 9, 2002 Volumen 8, 2001 Volumen 7, 2000 Volumen 6, 1999 Volumen 5, 1998 Volumen 4, 1997 Volumen 3, 1996 Volumen 2, 1995 Volumen 1, 1994

Journal of Enhanced Heat Transfer

DOI: 10.1615/JEnhHeatTransf.v8.i1.30
pages 23-40

Transitional Heat Transfer and Turbulent Characteristics of Drag-reducing Flow Through a Contracted Channel

Pei-Wen Li
Department of Mechanical Engineering, Kyoto University Kyoto 606-8501, Japan
Yasuo Kawaguchi
Turbomachinery Research Group, Institute for Energy Utilization, National Institute of Advanced Industrial Science and Technology, 1-2 Namiki, Tsukuba, Ibaraki 305-8564, Japan
Akira Yabe
Mechanical Engineering Laboratory, Ministry of International Trade and Industry, 1-2 Namiki, Tsukuba, Ibaraki 305 Japan

SINOPSIS

Accompanying the significant reduction of drag of turbulent flow when a drag-reducing surfactant is used, there is a serious reduction of heat transfer, typically 80%. Since the drag reduction can be terminated by a large wall shear stress, the drag-reducing flow of surfactant solution has a special property of the diameter effect. Based on this, a contracted section was designed in a two-dimensional channel to control the drag-reducing flow of a surfactant solution so as to produce turbulence for heat transfer purposes when it passes through the contracted part at certain Reynolds numbers. The same level of turbulence intensity as that of water flow is approached when the surfactant solution passes through the contracted section at certain Reynolds numbers. The heat transfer coefficient thus achieves 70 to 80 percent of that of water flow in the contracted section. In the non-contracted section the friction drag keeps the low level as drag-reducing flow. It is shown that the termination of the drag-reducing effect of the surfactant solution within a heat exchanger is possible by using the present method. The studied surfactant solution is CTAC/NaSal/Water at the temperature of around 30°C with the concentration ranging from 30 ppm to 60 ppm.