Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Critical Reviews™ in Biomedical Engineering
SJR: 0.207 SNIP: 0.376 CiteScore™: 0.79

ISSN Imprimir: 0278-940X
ISSN En Línea: 1943-619X

Volumes:
Volumen 47, 2019 Volumen 46, 2018 Volumen 45, 2017 Volumen 44, 2016 Volumen 43, 2015 Volumen 42, 2014 Volumen 41, 2013 Volumen 40, 2012 Volumen 39, 2011 Volumen 38, 2010 Volumen 37, 2009 Volumen 36, 2008 Volumen 35, 2007 Volumen 34, 2006 Volumen 33, 2005 Volumen 32, 2004 Volumen 31, 2003 Volumen 30, 2002 Volumen 29, 2001 Volumen 28, 2000 Volumen 27, 1999 Volumen 26, 1998 Volumen 25, 1997 Volumen 24, 1996 Volumen 23, 1995

Critical Reviews™ in Biomedical Engineering

DOI: 10.1615/CritRevBiomedEng.2016016365
pages 73-89

Opportunities and Challenges of 7 Tesla Magnetic Resonance Imaging: A Review

Muhammad Irfan Karamat
Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, ON, Canada
Sahar Darvish-Molla
Department of Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, ON, Canada
Alejandro Santos-Diaz
McMaster School of Biomedical Engineering, McMaster University, Hamilton, ON, Canada; Imaging Research Centre, St. Joseph's Healthcare, Hamilton, ON, Canada

SINOPSIS

The desire to achieve clinical ultra-high magnetic resonance imaging (MRI) systems stems from the fact that higher field strength leads to higher signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and spatial resolution. During last few years 7T MRI systems have become a quasi standard for ultra-high field MRI (UhFMRI) systems. This review presents a detailed account of opportunities and challenges associated with a clinical 7T MRI system for cranial and extracranial imaging. As with all of the previous transitions to higher field strengths, the switch from high to UhFMRI is not easy. The engineering and scientific community have to overcome challenges like magnetic field inhomogeneity, patient safety and comfort issues, and cost and related problems in order to achieve a clinically viable UhFMRI system. In addition, a large number of clinical studies are still required to show the improvements in quality of diagnostics that would come with 7T MRI, in order to bring such a research tool to the clinic.


Articles with similar content:

Neuromuscular Stimulation for Motor Neuroprosthesis in Hemiplegia
Critical Reviews™ in Physical and Rehabilitation Medicine, Vol.12, 2000, issue 1
Ronald Triolo, Kevin Kilgore, John Chae, David Yu
Advances in Multimodality Imaging Through a Hybrid PET/MRI System
Critical Reviews™ in Biomedical Engineering, Vol.37, 2009, issue 6
Ali Fatemi-Ardekani, Markad V. Kamath, Navid Samavati, Jin Tang
Functional Electrical Stimulation for Ejaculation
Journal of Long-Term Effects of Medical Implants, Vol.12, 2002, issue 3
Tyler C. Wind, Richard Edlich, Stuart S. Howards
Gemini Amphiphiles: A Novel Class of Nonviral Gene Delivery Vectors
Critical Reviews™ in Therapeutic Drug Carrier Systems, Vol.27, 2010, issue 3
M.R. Yadav, Kaustubh Jinturkar, Ambikanandan Misra, Mukesh Kumar
A Systematic Review of All Smart Phone Applications Specifically Aimed for Use as a Scoliosis Screening Tool
Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 1
Jadie Detolla, Andrew Merola, Steven A. Burekhovich, Qais Naziri, Chibukem Akamnanu, Carl B. Paulino, Westley Hayes