Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Critical Reviews™ in Biomedical Engineering
SJR: 0.207 SNIP: 0.376 CiteScore™: 0.79

ISSN Imprimir: 0278-940X
ISSN En Línea: 1943-619X

Volumes:
Volumen 47, 2019 Volumen 46, 2018 Volumen 45, 2017 Volumen 44, 2016 Volumen 43, 2015 Volumen 42, 2014 Volumen 41, 2013 Volumen 40, 2012 Volumen 39, 2011 Volumen 38, 2010 Volumen 37, 2009 Volumen 36, 2008 Volumen 35, 2007 Volumen 34, 2006 Volumen 33, 2005 Volumen 32, 2004 Volumen 31, 2003 Volumen 30, 2002 Volumen 29, 2001 Volumen 28, 2000 Volumen 27, 1999 Volumen 26, 1998 Volumen 25, 1997 Volumen 24, 1996 Volumen 23, 1995

Critical Reviews™ in Biomedical Engineering

DOI: 10.1615/CritRevBiomedEng.v28.i56.150
pages 137-144

Prospects for Applying Fluorescence Spectroscopy to Diagnose the Hard Tissues of a Tooth

I. M. Taubinsky
Institute of General Physics of the Russian Academy of Sciences (Moscow), Russia
M. T. Alexandrov
I. M. Sechenov Medical Academy, Russia
S. Yu. Koz'ma
Institute of General Physics of the Russian Academy of Sciences, Russia
V. V. Chernyi
Moscow State Institute of Electronic Engineering, Russia

SINOPSIS

This article deals with the autofluorescence spectra from the hard tissues of a tooth, both in norm and pathology. An investigation was made on 30 extracted human teeth. The measurements were made both for the intact hard tissues of a tooth, such as enamel, dentine, cementum, and root canal, and for the tissues pathologically affected by a caries (superficial, intermediate, and deep) and by a dental calculus. It was found that the fluorescent spectra from enamel, dentine, cementum, and from the regions affected by a Caries and dental calculus were identical in form. All the spectra revealed a maximum near 700 nm. However, the intact and affected hard tissues were greatly different in the integral fluorescent intensity. Dental calculus was found to produce the most pronounced fluorescent intensity, whereas the carious regions produced a slightly weaker fluorescent intensity. On the contrary, the intact hard tissues of a tooth exhibited the poorest fluorescent intensity.


Articles with similar content:

Bone Ingrowths to Press-Fit and Loose-Fit Implants: Comparisons between Titanium and Hydroxyapatite
Journal of Long-Term Effects of Medical Implants, Vol.16, 2006, issue 2
Mikael Sundfeldt, Olav Reikeras, Carina B. Johansson
EXPERIMENTAL STUDY OF COHERENT FLOW STRUCTURES BEHIND TWO SIMILAR NORMAL FLAT PLATES IN TANDEM ARRANGEMENT
Heat Transfer Research, Vol.50, 2019, issue 18
Hasan Hacisevki, Arian Bahrami
Histological Evaluation, in Rabbit Tibiae, of Osseointegration of Mini-implants in Sites Prepared with Er:YAG Laser versus Sites Prepared with Traditional Burs
Journal of Long-Term Effects of Medical Implants, Vol.16, 2006, issue 2
Sergio Salina, Giovanna Iezzi, Alessandro Colombo, Carlo Maiorana, Filippo Fontana, Adriano Piattelli
Histologic and Histomorphometric Analysis of an Immediately Loaded Implant Retrieved from Man after 14 Months of Loading
Journal of Long-Term Effects of Medical Implants, Vol.15, 2005, issue 5
Giovanna Iezzi, Antonio Scarano, Marco Degidi, Adriano Piattelli
Comparison of the Effects of Different Implant Apical Designs on the Magnitude and Distribution of Stress and Strain in Bone: A Finite Element Analysis Study
Journal of Long-Term Effects of Medical Implants, Vol.24, 2014, issue 2-3
Hasti Torabi, Mohammad Reza Movahhedy, Ardeshir Lafzi, Saeed Raoofi, Mahdi Kadkhodazadeh, Maryam Khademi, Reza Amid