Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2015010735
pages 243-258

TEMPERATURE FLUCTUATION CHARACTERISTICS OF POOL BOILING WITHIN SPACE-CONFINED STRUCTURES

Xuehu Ma
Liaoning Key Laboratory of Clean Utilization of Chemical Resources, Institute of Chemical Engineering, Dalian University of Technology, Dalian 116024, China
Wei Xu
Institute of Chemical Engineering, Liaoning Key Laboratory of Clean Utilization of Chemical Resources, Dalian University of Technology, Dalian, China
Chunjian Yu
Institute of Chemical Engineering, Dalian University of Technology, Dalian 116012, China
Zhong Lan
Institute of Chemical Engineering, Liaoning Key Laboratory of Clean Utilization of Chemical Resources, Dalian University of Technology, Dalian, China
Zhaolong Hao
Institute of Chemical Engineering, Dalian University of Technology, Dalian 116012, China

SINOPSIS

In this paper, the surface temperature fluctuation magnitude and frequency at the nucleation sites in the process of boiling a specially designed space-confined structure is investigated using infrared thermography. Water and ethanol are used as working fluids. The results show that the magnitude of temperature fluctuations is less than 1 K in experiments, while the theoretical prediction of this value is equal to at least 5 K if bubbles are in direct contact with the heating surface. The average temperature fluctuation frequencies and the average bubble departure frequencies on plain and E0.15 surfaces are close in value to each other. A remarkable discrepancy can be found between the surface temperature fluctuation frequency and the bubble departure frequency. The experimental results illustrate that bubbles are not in direct contact with the heating surface, instead, a microlayer of liquid exists between bubbles and heating surface all the time. The bubbles predominately affect the boiling heat transfer characteristics through the temperature fluctuation of the liquid layer.


Articles with similar content:

The Influence of Single Bubble Growth and Bubble Coalescence on Boiling Heat Transfer
International Heat Transfer Conference 15, Vol.38, 2014, issue
Peter Stephan, Axel Sielaff
A THEORETICAL MODEL FOR BUBBLE FREQUENCY IN NUCLEATE POOL BOILING INCLUDING SURFACE EFFECTS
International Heat Transfer Conference 6, Vol.1, 1978, issue
Ross L. Judd, M. S. M. Shoukri
BUBBLE ENERGY AND LATENT HEAT FLUX ESTIMATION
Heat Transfer Research, Vol.50, 2019, issue 1
Jure Voglar
HIGH-SPEED INFRARED THERMOGRAPHIC INVESTIGATION OF WATER SUBCOOLED POOL BOILING ON THIN METAL FOILS
Interfacial Phenomena and Heat Transfer, Vol.4, 2016, issue 4
Jure Voglar, Franc Cimerman, Iztok Golobic, Matevž Zupancic
MODIFICATION OF THE NUCLEATE BOILING HYSTERESIS IN THE POOL BOILING OF FLUOROCARBONS
International Heat Transfer Conference 10, Vol.12, 1994, issue