Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2017017578
pages 1237-1262

CONVERGENCE ANGLES EFFECT ON HEAT TRANSFER CHARACTERISTICS IN A WEDGED DUCT WITH DIMPLES/PROTRUSIONS

Lei Luo
School of Energy Science and Engineering, Harbin Institute of Technology, Harbin, 150001, China
Wei Du
School of Energy Science and Engineering, Harbin Institute of Technology, Harbin, 150001, China
Fengbo Wen
School of Energy Science and Engineering, Harbin Institute of Technology, Harbin, 150001, China
Songtao Wang
School of Energy Science and Engineering, Harbin Institute of Technology, Harbin, 150001, China
Zhiqi Zhao
School of Energy Science and Engineering, Harbin Institute of Technology, Harbin, 150001, China

SINOPSIS

In this study, numerical simulations are performed to investigate the effects of convergence angle on the flow structure, end-wall heat transfer, and friction factor in a wedged duct with dimples/protrusions. The convergence angles are set as 0°, 6.3°, and 12.5°, respectively. The end wall of the wedged duct is arranged with dimples or protrusions in staggered layout. The normalized depth of a dimple/protrusion is set as 0.2. The Reynolds number is between 8,500 and 60,000. Results for the flow field, end-wall heat transfer, and friction factor are considered. The results show that the increase in the convergence angle introduces a pressure gradient pointing from the wedged duct top to the end-wall side. Thus, the flow impingement and flow acceleration are increased, while the flow recirculation is decreased. On the other hand, the secondary edge vortex in the wedged duct with dimples is also increased as the convergence angle increases, which contributes to the heat transfer augmentation. For the wedged duct with protrusions, the increase in the convergence angle enhances the local heat transfer by intensifying the leading edge impingement. However, the flow structure in the duct with protrusions does not change so remarkably as in the dimpled duct. It is also found that the increase in the convergence angle significantly increases the friction factor with moderate heat transfer augmentation. The thermal performance indicates that the large convergence angle reduces the thermal performance remarkably. The value is reduced from 1.7 to 1.35 as the convergence angle increases.


Articles with similar content:

NUMERICAL INVESTIGATION OF WALL CURVATURE EFFECTS ON HEAT TRANSFER AND FILM COOLING EFFECTIVENESS
Heat Transfer Research, Vol.47, 2016, issue 6
M. Taiebi-Rahni, A. Shalchi-Tabrizi, Gongnan Xie, Masoud Asadi
NUMERICAL ANALYSIS OF ENHANCED HEAT TRANSFER IN DEVELOPING LAMINAR PIPE FLOW USING DECAYING SWIRL AT THE INLET
Journal of Enhanced Heat Transfer, Vol.23, 2016, issue 4
Mohammad O. Hamdan
EFFECTS OF PIN FIN CONFIGURATIONS ON HEAT TRANSFER AND FRICTION FACTOR IN AN IMPROVED LAMILLOY COOLING STRUCTURE
Heat Transfer Research, Vol.48, 2017, issue 7
Lei Wang, Bengt Sunden, Lei Luo, Songtao Wang, Chenglong Wang
Numerical Investigations on Enhancement of Heat Transfer in a Compact Fin-and-Tube Heat Exchanger Using Delta Winglet Type Vortex Generators
Journal of Enhanced Heat Transfer, Vol.6, 1999, issue 1
A. A. Bastani Jahromi, Gautam Biswas, Nimai K. Mitra
PREDICTION OF LAMINAR HEAT TRANSFER AND FLOW IN PLANE ENLARGED CHANNELS
International Heat Transfer Conference 9, Vol.6, 1990, issue
Terukazu Ota, Y. Toda