Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Heat Transfer Research
Factor de Impacto: 0.404 Factor de Impacto de 5 años: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN En Línea: 2162-6561

Volumes:
Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2016010434
pages 855-863

OBSERVATION OF HEAT TRANSFER IN OSCILLATING FLOW WITHIN A CIRCULAR CHANNEL

Ke Tang
Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
Jiale Huang
Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
Wentao Tang
Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
Juan Yu
Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China
Tao Jin
Institute of Refrigeration and Cryogenics, Zhejiang University, Hangzhou 310027, China

SINOPSIS

A periodical reversion of velocity direction distinguishes an oscillating flow from a common unidirectional steady flow. This study focuses on heat transfer in oscillating flow within a circular channel. An experimental apparatus operating at a frequency of 0.3-1.1 Hz and at a near atmospheric pressure has been built for measuring the heat transfer rate. Typical experimental data on the oscillating pressure, velocity, temperature difference (between the central fluid and the channel wall), on the heat flux at the channel wall are presented. A zero-order Nusselt number is used to characterize the time-averaged heat transfer of the oscillating flow. A marked increase in the zero-order Nusselt number with increase in the Peclet number is observed, which indicates that the raised frequency can effectively enhance heat transfer in oscillating flow.


Articles with similar content:

THERMALLY INDUCED TWO-PHASE OSCILLATING FLOW IN A CAPILLARY TUBE: EXPERIMENTAL INVESTIGATIONS
Heat Pipe Science and Technology, An International Journal, Vol.5, 2014, issue 1-4
Sameer Khandekar, Jocelyn Bonjour, Frederic Lefevre, Manoj Rao
Bubble dynamics and acoustic phenomena in subcooled pool boiling
International Heat Transfer Conference 12, Vol.40, 2002, issue
Jens J. Schroder, Andreas Bode
NATURAL CIRCULATION EXPERIMENTS IN AN OSCILLATING FORCE FIELD
International Heat Transfer Conference 3 , Vol.15, 1966, issue
John B. Woodward III, Herman Merte, Jr.
BOILING INCIPIENCE AND HEAT TRANSFER IN A MICROTUBE: EXPERIMENTAL MEASUREMENTS USING LIQUID CRYSTAL THERMOGRAPHY
International Heat Transfer Conference 13, Vol.0, 2006, issue
Ibrahim Hassan, R. Muwanga
A STUDY ON THE THERMAL-HYDRAULIC PHENOMENA OF DECAY HEAT REMOVAL SYSTEM USING THE CLOSED TWO-PHASE THERMOSIPHON LOOP
Proceedings of Symposium on Energy Engineering in the 21st Century (SEE2000) Volume I-IV, Vol.0, 2000, issue
Goon Cherl Park, Yehchan Ahn, Moo Hwan Kim