Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Heat Transfer Research
Factor de Impacto: 0.404 Factor de Impacto de 5 años: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN En Línea: 2162-6561

Volumes:
Volumen 51, 2020 Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2014006774
pages 293-309

EXPERIMENTAL INVESTIGATION OF A REHEATING TWO-STAGE ADSORPTION CHILLER APPLYING FIXED CHILLED WATER OUTLET CONDITIONS

I Gusti Agung Bagus Wirajati
Graduate School of Bio-Applications and Systems Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei-shi, 184-8588, Tokyo, Japan; Bali State Polytechnic, Bukit Jimbaran, Kuta Selatan, Bali 80364
Atsushi Akisawa
Graduate School of Bio-Applications and Systems Engineering (BASE), Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei-shi, Tokyo 184-8588, Japan
Yuki Ueda
Graduate School of Bio-Applications and Systems Engineering (BASE), Tokyo University of Agriculture and Technology, 2-24-16 Nakacho, Koganei-shi, Tokyo 184-8588, Japan
Takahiko Miyazaki
Faculty of Engineering Sciences, Kyushu University, 6-1 Kasuga-koen, Kasuga-shi, Fukuoka, 816-8580, Japan

SINOPSIS

The adsorption refrigeration chiller is environmentally friendly because of the use of a natural refrigerant and the use of a low-grade thermal energy as the driving energy source. In this paper, an experimental investigation of a reheating two-stage adsorption chiller was conducted, and the working principle of the cycle was also introduced. The coefficient of performance and the cooling capacity were calculated to analyze the performance of the chiller. Our objective was to identify the effect of the temperature of the heat source and the effect of cycle time on the performance if the chilled water outlet temperature is fixed at 9° during the experiment. Experimental results showed that the performance of the chiller improved with increasing heat source temperature and that a total cycle time between 2000 to 2500 s yields better performance for the chiller.