Suscripción a Biblioteca: Guest
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones
Heat Transfer Research
Factor de Impacto: 0.404 Factor de Impacto de 5 años: 0.8 SJR: 0.264 SNIP: 0.504 CiteScore™: 0.88

ISSN Imprimir: 1064-2285
ISSN En Línea: 2162-6561

Volumes:
Volumen 50, 2019 Volumen 49, 2018 Volumen 48, 2017 Volumen 47, 2016 Volumen 46, 2015 Volumen 45, 2014 Volumen 44, 2013 Volumen 43, 2012 Volumen 42, 2011 Volumen 41, 2010 Volumen 40, 2009 Volumen 39, 2008 Volumen 38, 2007 Volumen 37, 2006 Volumen 36, 2005 Volumen 35, 2004 Volumen 34, 2003 Volumen 33, 2002 Volumen 32, 2001 Volumen 31, 2000 Volumen 30, 1999 Volumen 29, 1998 Volumen 28, 1997

Heat Transfer Research

DOI: 10.1615/HeatTransRes.2018017363
pages 1171-1183

NUMERICAL INVESTIGATION OF THERMAL PERFORMANCE OF A CRYOGENIC OSCILLATING HEAT PIPE

Qing Liang
Institute of Electrical Engineering, Chinese Academy of Sciences, Beij ing 100190, China; School of Civil Engineering, Henan Polytechnic University, Jiaozuo 454000, China; University of Chinese Academy of Sciences, Beij ing 100049, China
Yi Li
Institute of Electrical Engineering, Chinese Academy of Sciences, Beij ing 100190, China
Qiuliang Wang
Institute of Electrical Engineering, Chinese Academy of Sciences, Beij ing 100190, China; University of Chinese Academy of Sciences, Beij ing 100049, China

SINOPSIS

The oscillating heat pipe (OHP) with simple structure and high heat transfer effi ciency has been proposed recently for cryogenic use. In this paper, a model of fluid flow and heat transfer on multiple liquid slugs and vapor plugs in an OHP has been developed. The cryogenic OHP with working fluid of nitrogen is studied using the model. Oscillatory flow and circulatory flow are observed. The mass flow rate of liquid slugs and the mean wall temperature of the evaporator section are calculated. Furthermore, the effective thermal conductivity of the cryogenic OHP is determined, which shows much higher thermal performance than that of high purity metal. The effects of the heat input and the filling ratio on the effective thermal conductivity are discussed. Finally, the calculated effective thermal conductivity is compared with experimental results, and it is seen that this model correctly predicts the thermal performance of a cryogenic OHP in the case of a medium and low heat input.


Articles with similar content:

EXPERIMENTAL INVESTIGATION OF THE THERMAL PERFORMANCE OF WRAPAROUND LOOP HEAT PIPE HEAT EXCHANGER FOR HEAT RECOVERY IN AIR HANDLING UNITS
Heat Transfer Research, Vol.48, 2017, issue 14
Yonglin Ju, Manfeng Li
FORCED CONVECTION HEAT TRANSFER OF NON-NEWTONIAN CROSS FLUID IN A SQUARE CAVITY
Heat Transfer Research, Vol.48, 2017, issue 5
Xinxin Zhang, Liancun Zheng, Jinhu Zhao
COMPARATIVE STUDY OF FLUID FLOW AND HEAT TRANSFER IN RECTANGULAR AND WAVY MICROCHANNEL
Computational Thermal Sciences: An International Journal, Vol.9, 2017, issue 6
Prateek Kumar Gupta, Shobha Lata Sinha, Satish Kumar Dewangan
HEAT TANSFER PERFORMANCE OF OSCILLATING HEAT PIPE BY DIFFERENCE OF SURFACE CHARACTERISTICS
Heat Pipe Science and Technology, An International Journal, Vol.5, 2014, issue 1-4
Takamu Kanayama, Hiroki Nagai, Takurou Daimaru
Impedance Characteristics of Diodes Operating Jointly and Having Negative Differential Conductivity
Telecommunications and Radio Engineering, Vol.61, 2004, issue 2-6
E. D. Prokhorov, O. V. Botsula