Strength of Syndesmosis Fixation: Two TightRope versus One TightRope with Plate-and-Screw Construct

Volumen 26, Edición 2, 2016, pp. 161-165
DOI: 10.1615/JLongTermEffMedImplants.2016016538
Get accessGet access

SINOPSIS

Injuries involving the distal tibiofibular syndesmosis can lead to critical destabilization of the ankle mortise. Although specific indications for operative fixation remain unclear, accurate reduction of the syndesmosis has been correlated with the best functional outcomes. The purpose of this study was to evaluate the maximum torque and rotation to failure after fixation with a novel construct. Seven pairs (14 ankles) of embalmed cadaveric lower legs, disarticulated at the knee, were obtained. Each pair was randomly assigned to receive either two TightRopes (Arthrex) or a plate-and-screw construct with one TightRope. All samples were mechanically tested in torsion to determine peak torque, torsional stiffness, and the maximum rotation angle at which failure occurred. Differences between the groups were compared using paired Student's t test. The maximum torque to failure after fixation was not significantly different between the two TightRopes (28.8 N*m; range, 7.3–49.7 N*m) and the one TightRope group (29.5 N*m; range, 9.2–44.9 N*m; p = 0.92). The maximum rotation to fracture after fixation was not significantly different between the two TightRopes (33.3 degrees; range, 21.6–57.0 degrees) and one TightRope group (38.6 degrees; range, 23.0–73.9 degrees). All specimens failed with the fracture of the fibula at the level of the inferior syndesmotic screw. The similar load to failure of the two TightRope and the one TightRope and plate-and-screw plate suggested similar stiffness between the two constructs. The addition of the plate may improve distribution of forces at the level of syndesmosis, reducing stress risers and decreasing the risk of failure, as demonstrated by a lower rotation to failure of the one TightRope with plate-and-screw construct. In addition, this construct is not likely to not be associated with any substantial cost increase. Further clinical studies may further elucidate the role of plate and/or TightRope augmentation to syndesmosis fixation.

CITADO POR
  1. Beck Edward C., Gowd Anirudh K., Nabor Darren, Waterman Brian R., Cortical Button Fixation for Proximal Tibiofibular Instability: A Technical Report, Arthroscopy Techniques, 9, 9, 2020. Crossref

1736 Vistas de artículos 66 Descargas de artículos Métrica
1736 PUNTOS DE VISTA 66 DESCARGAS 1 Crossref CITAS Google
Scholar
CITAS

Artículos con contenido similar:

A Comparison of the Compressive Strength of Various Distal Locking Screw Options in the Treatment of Tibia Fractures with Intramedullary Nails Journal of Long-Term Effects of Medical Implants, Vol.21, 2011, issue 3
Westley T. Hayes, Fred Xavier, E. Goldwyn, R. Elkhechen, A. Goldman, M. Berdichevsky, A. Carrer, William P. Urban, Subrata Saha
Reference Values for Isometric Ankle Strength: A Scoping Literature Review and Comparison with Novel Data from 683 Athletes Critical Reviews™ in Physical and Rehabilitation Medicine, Vol.35, 2023, issue 1
Žiga Kozinc, Luka Kejžar, Nejc Šarabon, Darjan Smajla
Failure of a Medial Unicompartmental Knee Replacement due to Metal Allergy Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 4
Shamsul Khan, Theodore Balfousias, George Tselentakis, Bala Srikanth, Alexandros P. Apostolopoulos
Incidence and Future Projections of Periprosthetic Femoral Fracture Following Primary Total Hip Arthroplasty: An Analysis of International Registry Data Journal of Long-Term Effects of Medical Implants, Vol.25, 2015, issue 4
Robert Pivec, Peter M. Bonutti, Jeffery J. Cherian, Aditya V. Maheshwari, Michael A. Mont, Bhaveen V. Kapadia, Kimona Issa
Large Diameter Total Hip Replacement for Acute Displaced Femoral Neck Fracture Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 1
James W. Pritchett

Próximos Artículos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka