pages 161-165

Strength of Syndesmosis Fixation: Two TightRope versus One TightRope with Plate-and-Screw Construct

Justin Tsai
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center/University Hospital Brooklyn, Brooklyn, NY
Robert Pivec
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center/University Hospital Brooklyn, Brooklyn, NY
Julio J. Jauregui
Center for Joint Preservation and Replacement, Rubin Institute for Advanced Orthopedics, Sinai Hospital of Baltimore, Baltimore, Maryland; Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center/University Hospital Brooklyn, Brooklyn, NY
Westley T. Hayes
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center/University Hospital Brooklyn, Brooklyn, NY
Marlon McLeold
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center/University Hospital Brooklyn, Brooklyn, NY
Qais Naziri
Rubin Institute for Advanced Orthopedics, Center for Joint Preservation and Reconstruction, Sinai Hospital of Baltimore, Baltimore, Maryland; Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center/University Hospital Brooklyn, Brooklyn, NY
Bhaveen V. Kapadia
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center/University Hospital Brooklyn, Brooklyn, NY
Subrata Saha
Affiliate Professor, Department of Restorative Dentistry Affiliate Instructor, Department of Oral and Maxillofacial Surgery School of Dentistry, University of Washington, Seattle, Washington 98195-6365, USA; Courtesy Professor, Department of Biomedical Engineering, Florida International University, Miami, Florida 33174, USA
Jaime A. Uribe
Department of Orthopaedic Surgery and Rehabilitation Medicine, SUNY Downstate Medical Center/University Hospital Brooklyn, Brooklyn, NY

SINOPSIS

Injuries involving the distal tibiofibular syndesmosis can lead to critical destabilization of the ankle mortise. Although specific indications for operative fixation remain unclear, accurate reduction of the syndesmosis has been correlated with the best functional outcomes. The purpose of this study was to evaluate the maximum torque and rotation to failure after fixation with a novel construct. Seven pairs (14 ankles) of embalmed cadaveric lower legs, disarticulated at the knee, were obtained. Each pair was randomly assigned to receive either two TightRopes (Arthrex) or a plate-and-screw construct with one TightRope. All samples were mechanically tested in torsion to determine peak torque, torsional stiffness, and the maximum rotation angle at which failure occurred. Differences between the groups were compared using paired Student's t test. The maximum torque to failure after fixation was not significantly different between the two TightRopes (28.8 N*m; range, 7.3–49.7 N*m) and the one TightRope group (29.5 N*m; range, 9.2–44.9 N*m; p = 0.92). The maximum rotation to fracture after fixation was not significantly different between the two TightRopes (33.3 degrees; range, 21.6–57.0 degrees) and one TightRope group (38.6 degrees; range, 23.0–73.9 degrees). All specimens failed with the fracture of the fibula at the level of the inferior syndesmotic screw. The similar load to failure of the two TightRope and the one TightRope and plate-and-screw plate suggested similar stiffness between the two constructs. The addition of the plate may improve distribution of forces at the level of syndesmosis, reducing stress risers and decreasing the risk of failure, as demonstrated by a lower rotation to failure of the one TightRope with plate-and-screw construct. In addition, this construct is not likely to not be associated with any substantial cost increase. Further clinical studies may further elucidate the role of plate and/or TightRope augmentation to syndesmosis fixation.


Articles with similar content:

A Comparison of the Compressive Strength of Various Distal Locking Screw Options in the Treatment of Tibia Fractures with Intramedullary Nails
Journal of Long-Term Effects of Medical Implants, Vol.21, 2011, issue 3
Westley T. Hayes, Fred Xavier, E. Goldwyn, R. Elkhechen, A. Goldman, M. Berdichevsky, A. Carrer, William P. Urban, Subrata Saha
Rotational Deformity of the First Ray Precludes Accurate Distal Metatarsal Articular Angle Measurement in Hallux Valgus
Journal of Long-Term Effects of Medical Implants, Vol.28, 2018, issue 1
Barbara Freeman, Robert Pivec, Jaime A. Uribe, Qais Naziri, David B. Frumberg, Lee Bloom
Optimization of Spinal Implant Screw for Lower Vertebra through Finite Element Studies
Journal of Long-Term Effects of Medical Implants, Vol.24, 2014, issue 2-3
Santanu Majumder, Jayanta Kumar Biswas, Santanu Kr. Karmakar, Partha Sarathi Banerjee, Amit Roychowdhury, Subrata Saha
A 3-D FEM Analysis of Single and Multiple Screw-Root Dental Implant Fixed in a Mandible
Critical Reviews™ in Biomedical Engineering, Vol.28, 2000, issue 3&4
Amit Roychowdhury, S. Pal
Stress and Strain Distribution Patterns in Bone around Tissue- and Bone-Level Implant-Supported Mandibular Overdentures Using Three-Dimensional Finite-Element Analysis
Journal of Long-Term Effects of Medical Implants, Vol.29, 2019, issue 3
Farhad Hajizadeh, Sanaz Panahi