Cyclic Loads Do Not Compromise Functionality of the Interspinous Spacer or Cause Damage to the Spinal Segment: An In Vitro Analysis

Volumen 18, Edición 4, 2008, pp. 289-302
DOI: 10.1615/JLongTermEffMedImplants.v18.i4.30
Get accessGet access

SINOPSIS

Study Design. A biomechanical study to evaluate the effects of interspinous spacer under cyclic complex loading. Objectives. To determine the risk of device migration and to assess damage on the device and specimen under extreme coupled motion. Another objective was to evaluate the effect on vertebral foramen and canal dimensions after spacer implantation. Summary of Background Data. Interspinous spacers are a relatively new treatment option that are clinically exposed to complex loads. However, the biomechanical performance of these spacers has not been well characterized. Methods. Six human cadaveric motion segments were used for this study. The interspinous spacer (SuperionTM, Vertiflex Inc, California) was tested for 5° extension/10° flexion coupled with an axial rotation of ±3°. CT images were taken for specimens in neutral, 5° extension, and 10° flexion before and after the implantation of the spacer. Vertebral foramen and canal dimensions were quantified. Results. There was no device migration or subsidence. Specimens did not sustain any significant injury during testing. Canal area was minimally altered and foramen height, width, and area increased in extension and were statistically significant as compared to intact. Conclusion. Interspinous spacer effectively prevents the motion at the implanted level and does not change the anatomy significantly.

CITADO POR
  1. Loguidice Vito, Bini Walter, Shabat Shay, Miller Larry E, Block Jon E, Rationale, design and clinical performance of the Superion®Interspinous Spacer: a minimally invasive implant for treatment of lumbar spinal stenosis, Expert Review of Medical Devices, 8, 4, 2011. Crossref

  2. Miller Larry E., Block Jon E., Interspinous Spacer Implant in Patients with Lumbar Spinal Stenosis: Preliminary Results of a Multicenter, Randomized, Controlled Trial, Pain Research and Treatment, 2012, 2012. Crossref

  3. Baranto Adad, Hagelberg Christian, Hvannberg Jonas, Ekström Lars, Halldin Klas, Brisby Helena, Interspinous Process Implants Causes Wear of the Spinous Processes in Patients Treated for Spinal Stenosis—An Experimental Biomechanical Study with Comparison to Clinical Cases, Open Journal of Orthopedics, 06, 07, 2016. Crossref

  4. Palepu V., Kodigudla M., Goel V. K., Biomechanics of Disc Degeneration, Advances in Orthopedics, 2012, 2012. Crossref

  5. Sénégas Jacques, A Word from the Inventor of Intervertebral Dynamic Fixation: On Interspinous Devices, in Advanced Concepts in Lumbar Degenerative Disk Disease, 2016. Crossref

  6. Cha Thomas D., Dazley Justin M., Khan Safdar N., Lumbar Spinal Stenosis, in Minimally Invasive Spine Surgery, 2014. Crossref

  7. Bini Walter, Miller Larry E, Block Jon E, Minimally Invasive Treatment of Moderate Lumbar Spinal Stenosis with the Superion® Interspinous Spacer, The Open Orthopaedics Journal, 5, 1, 2011. Crossref

  8. Nwosu Kenneth C., Khan Safdar N., Cha Thomas D., Lumbar Spinal Stenosis, in Minimally Invasive Spine Surgery, 2019. Crossref

532 Vistas de artículos 16 Descargas de artículos Métrica
532 PUNTOS DE VISTA 16 DESCARGAS 8 Crossref CITAS Google
Scholar
CITAS

Artículos con contenido similar:

Prospective Evaluation of Bone Remodeling in Full-Arch Rehabilitations with Morse Taper Implants: A Case Series Study with One-Year Follow-Up Journal of Long-Term Effects of Medical Implants, Vol.32, 2022, issue 3
Carolina Accorsi Cartelli, Sergio Rocha Bernardes, Larissa Carvalho Trojan, Marcos Boaventura de Moura, Geninho Thomé, Ángel José Sánchez Reyes
Stress and Strain Distribution Patterns in Bone around Splinted Standard and Short Implants Placed at the Crestal Level and Subcrestally using Three- Dimensional Finite Element Analysis Journal of Long-Term Effects of Medical Implants, Vol.27, 2017, issue 1
Raheleh Akhavan Rasoolzadeh, Mahdi Kadkhodazadeh, Amir Mahmoudi Motlagh, Farshad Dehnavi, Reza Amid
Normal Passive Range of Motion for Supine Cervical Extension in a Symptom-Free Population Critical Reviews™ in Physical and Rehabilitation Medicine, Vol.28, 2016, issue 4
James A. Dauber, Melissa A. Kahlig, Cameron R. Yoho, Karlen M. Vinci
Measurements of Surface and Subsurface Damage in Retrieved Polyethylene Tibial Inserts of a Contemporary Design Journal of Long-Term Effects of Medical Implants, Vol.22, 2012, issue 1
Jan-M. Brandt, David W. Holdsworth, Matthew G Teeter, Eric R. Bohm, Douglas D. R. Naudie, Richard W. McCalden
Evaluation of Alveolar Crest Changes following Buccal Bone Overbuilding in Immediate Implantation Journal of Long-Term Effects of Medical Implants, Vol.26, 2016, issue 3
Amirhossein Moradi, Hamid Reza Arab, Mehrdad Radvar, Amir Moeintaghavi, Kazem Fatemi, Farid Shiezadeh

Próximos Artículos

Transfer of guided emergence profile developed using customized provisional implant restoration and cementation using an abutment replica technique- A case report. Vinay Sivaswamy, Balaji Anand S D, Jacob Mathew Philip, C J Venkatakrishnan, Narasimman M, Helen Mary Abraham, Pavithra B Marijuana use is Associated with Increased Rates of Hip Dislocation and Lower Insurance Reimbursement among THA Recipients Andrew Recker, Chukwuweike Gwam, Erin Kelly, Scott Douglas, Johannes Plate Surface modification of Mg alloy AZ91D using nanopowder mixed EDM for Biodegradable Implant Alok Kumar, Abhishek Singh The history of orthopedics in the long term: from general medicine to medical specialties Pavlos Altsitzioglou, Ioannis Zafeiris, Fotini Soucacos, Pantelis Limneos, Eleftheria Souliotis, Evanthia Mitsiokapa, Theodosis Saranteas, Andreas Mavrogenis COMPARISON OF ROUGHNESS, WETTABILITY AND SCANNING ELECTRON MICROSCOPY FEATURES BETWEEN SANDBLASTED ACID-ETCHED AND OXIDIZED TITANIUM DENTAL IMPLANTS Kshitiz Chhabra, Arvina Rajasekar CORRELATION BETWEEN PRIMARY STABILITY OF DENTAL IMPLANTS AND BONE DENSITY: A RETROSPECTIVE ANALYSIS Padmaja S, Arvina Rajasekar C-Reactive Protein and Erythrocyte Sedimentation Rates after total and unicompartmental knee arthroplasty - less implant equals quicker normalization Kasım Kılıçarslan, Ömer Faruk Naldöven, Enejd Veizi, Şahan Güven, Şahin Çepni, Ahmet Fırat COMPLICATIONS FOLLOWING SHORT FEMORAL NAIL FIXATION FOR INTETROCHANTERIC HIP FRACTURES. A RETROSPECTIVE STUDY Anastasia Vasilopoulou, Antonios Trichonas, Konstantinos Palaiologos, Emmanouel Antonogiannakis, Christos Nikakis, Stavros Angelis, Spyridon Maris, Christos Grekas , Efthimios Karadimas, Alexandros Apostolopoulos FEA: Connector Designs and Pontic Stress Distribution of Fixed Partial Denture Implant-Supported Metal Framework Saja Muhsin, Enas Mohammed, Khalid Bander Design and Frequency Stability Analysis of an Adaptive Neuro-Fuzzy Inference System based Artificial Pacemaker Controller in MATLAB Nader Jafarnia Dabanloo, Asghar Dabiriaghdam, Fereidoon Nooshirvan Rahatabad, Keivan Maghooli Complications following intraosseous injections of calcium phosphate bone cement in Subchondroplasty. Christos Zachariadis, Helen Leligou, Stauros Kourkoulis, Evaggelos Magnisalis, Panayiotis Papagelopoulos, Olga Savvidou The Impact of Patient Characteristics on Outcomes of Surgically Managed Vertebral Osteomyelitis in the United States: Insights from a National Database Study Jennifer Kurowicki, Stuart Changoor, Daniel Coban, Neil Patel, Kumar Sinha, Ki Hwang, Arash Emami ASSOCIATION OF AGE, GENDER AND SITE OF IMPLANT PLACEMENT - AN INSTITUTION BASED RETROSPECTIVE STUDY Harini Sri, Nabeel Ahmed, Keerthi Shasanka
Portal Digitalde Biblioteca Digital eLibros Revistas Referencias y Libros de Ponencias Colecciones Precios y Políticas de Suscripcione Begell House Contáctenos Language English 中文 Русский Português German French Spain